| Author |
Design |
Journal |
N |
Infection rate |
Flap procedure rate |
| Duckworth et al., 2017 [12] |
Prospective |
Journal of Bone & Joint Surgery |
32 plates, 30 tension bands |
13% (4) plates, 0% (0) tension bands |
0% (0) |
| Hume (&) Wiss, 1992 [8] |
Prospective |
Clinical Orthopaedics & Related Research |
3 plates, 37 tension bands, 1 screw |
0% (0) plates, 3% (1) tension bands |
0% (0) |
| Tarallo et al., 2014 [14] |
Retrospective |
Archives of Orthopaedic and Trauma Surgery |
45 plates, 33 tension bands |
0% (0) plates, 3% (1) tension bands |
0% (0) |
| Amini et al., 2015 [15] |
Retrospective |
American Journal of Orthopaedics |
10 plates 10 tension bands |
0% (0) plates, 0% (0) tension bands |
0% (0) |
| Schliemann et al., 2014 [16] |
Retrospective |
Acta Orthopaedica |
13 plates 13 tension bands |
8% (1) plates 8% (1) tension bands |
0% (0) |