Table 2. Sample Information.
Name | IUPAC Name | Source | Initial Purity/Mol Frac. | Purification Method | Final Purity/Mol Frac. | Analysis Method |
---|---|---|---|---|---|---|
propane | propane | Scott | 0.99999 | degassing | 0.99999 | GC/MSa |
water | water | b | >0.99999 | b | >0.99999 | resistivity |
p-xylene | p-xylene | Sigma-Aldrich | 0.997 | degassing | 0.997 | none |
R1234yf | 2,3,3,3-tetrafluoroprop-1-ene | Honeywell | 0.9996 | degassing | 0.9996 | GC/MS |
R1234ze(E) | trans-2,3,3,3-tetrafluoroprop-1-ene | Honeywell | 0.99993 | degassing | 0.99993 | GC/MS/IRc |
R1233zd(E) | trans-1-chloro-3,3,3-trifluoroprop-1-pene | Honeywell | 0.99985 | degassing | 0.99985 | GC/MS |
R1336mzz(Z) | cis-1,1,1,4,4,4-hexafluorobut-2-ene | Chemours | 0.9999 | degassing | 0.9999 | GC/QToF-MSd |
Gas chromatography/mass spectrometry.
The water sample was obtained from a commercial ultrapure laboratory water system that consisted of two ion-exchange stages, ultraviolet light dosing (to photo-oxidize organics), a third ion-exchange stage, and an ultrafiltration membrane; the resistivity of this water was 18.2 MΩ·cm.
Gas chromatography/mass spectrometry/infrared spectroscopy.
Gas chromatography/quadrupole time-of-flight mass spectroscopy.