Regression equation of liquidus temperature (°C) for LiF-NdF3 binary systema.

Range (mol%) Fitted equation
x NdF3 > 31% Y = 577.59 + 374.2858 × C + 422.1014 × C2
x NdF3 ≤ 31% Y = 848.59 − 287.4729 × C − 220.8428 × C2
a

Note: Y—liquidus temperature (°C); C—mole fraction of NdF3.