Skip to main content
. 2023 Aug 7;23(15):6994. doi: 10.3390/s23156994

Table 6.

Comparison of the FE and experimental results.

Mechanical Parameter Reference Sample Reinforced Sample
Experimental FEM Error Percentage Experimental FEM Error Percentage
Displacement corresponding to peak force (mm) 31.65 32.29 1.98 28.60 26.96 5.73
Maximum load (N) 204.86 233.01 12.07 250.09 272.31 8.16
Stiffness of the tube (N/mm) 7.99 8.38 4.65 9.87 10.68 7.57