Skip to main content
The British Journal of Ophthalmology logoLink to The British Journal of Ophthalmology
. 1991 May;75(5):280–283. doi: 10.1136/bjo.75.5.280

Visual assessment of infants: vernier targets for the Catford drum.

B Hopkisson 1, P Arnold 1, B Billingham 1, M McGarrigle 1, P Entwistle 1
PMCID: PMC1042355  PMID: 2036345

Abstract

Targets comprising a horizontal black line 5' thick offset by 1' were printed on strips to stick to the drums of the Catford Visual Acuity Apparatus. The 'vernier' targets so produced corresponded to the different sizes of Snellen letters from 6/6 to 2/60 when presented at 50 cm. Twenty-five children between the ages of 3 and 12 years with known amblyopia (mostly strabismic) were tested in a double blind trial to compare the visibility of the vernier targets with subjective Snellen acuity. All vernier results, both for better and amblyopic eye, were within one line of Snellen acuity. One hundred and twenty normal preverbal infants with normal eyes under the age of 2 1/2 years were tested with the vernier strips. Normal infants under the age of 6 months recorded a vision of 6/60-2/60; normal infants aged 6 to 12 months recorded 6/24-6/36, and infants between the ages of 1 and 2 1/2 years recorded 6/12-6/18.

Full text

PDF
280

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Atkinson J., Braddick O., Braddick F. Acuity and contrast sensivity of infant vision. Nature. 1974 Feb 8;247(5440):403–404. doi: 10.1038/247403a0. [DOI] [PubMed] [Google Scholar]
  2. Atkinson J., Braddick O., Moar K. Development of contrast sensitivity over the first 3 months of life in the human infant. Vision Res. 1977;17(9):1037–1044. doi: 10.1016/0042-6989(77)90007-4. [DOI] [PubMed] [Google Scholar]
  3. Atkinson J., Braddick O., Pimm-Smith E., Ayling L., Sawyer R. Does the Catford drum give an accurate assessment of acuity? Br J Ophthalmol. 1981 Sep;65(9):652–656. doi: 10.1136/bjo.65.9.652. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Banks M. S., Salapatek P. Acuity and contrast sensitivity in 1-, 2-, and 3-month-old human infants. Invest Ophthalmol Vis Sci. 1978 Apr;17(4):361–365. [PubMed] [Google Scholar]
  5. Catford G. V., Oliver A. Development of visual acuity. Arch Dis Child. 1973 Jan;48(1):47–50. doi: 10.1136/adc.48.1.47. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Dobson V., Teller D. Y., Belgum J. Visual acuity in human infants assessed with stationary stripes and phase-alternated checkerboards. Vision Res. 1978;18(9):1233–1238. doi: 10.1016/0042-6989(78)90109-8. [DOI] [PubMed] [Google Scholar]
  7. Gwiazda J., Brill S., Mohindra I., Held R. Infant visual acuity and its meridional variation. Vision Res. 1978;18(11):1557–1564. doi: 10.1016/0042-6989(78)90011-1. [DOI] [PubMed] [Google Scholar]
  8. Hess R. F., Campbell F. W., Greenhalgh T. On the nature of the neural abnormality in human amblyopia; neural aberrations and neural sensitivity loss. Pflugers Arch. 1978 Nov 30;377(3):201–207. doi: 10.1007/BF00584273. [DOI] [PubMed] [Google Scholar]
  9. Hess R., Jenkins S. Amblyopia cannot be explained by considering only detection thresholds. Perception. 1980;9(5):569–576. doi: 10.1068/p090569. [DOI] [PubMed] [Google Scholar]
  10. Katz B., Sireteanu R. Der Teller-Acuity-Card-Test: Möglichkeiten und Grenzen der klinischen Anwendung. Klin Monbl Augenheilkd. 1989 Jul;195(1):17–22. doi: 10.1055/s-2008-1046406. [DOI] [PubMed] [Google Scholar]
  11. Khan S. G., Chen K. F., Frenkel M. Subjective and objective visual acuity testing techniques. Arch Ophthalmol. 1976 Dec;94(12):2086–2091. doi: 10.1001/archopht.1976.03910040746009. [DOI] [PubMed] [Google Scholar]
  12. Levi D. M., Klein S. A. Vernier acuity, crowding and amblyopia. Vision Res. 1985;25(7):979–991. doi: 10.1016/0042-6989(85)90208-1. [DOI] [PubMed] [Google Scholar]
  13. Levi D. M., Klein S. Differences in vernier discrimination for grating between strabismic and anisometropic amblyopes. Invest Ophthalmol Vis Sci. 1982 Sep;23(3):398–407. [PubMed] [Google Scholar]
  14. Levi D. M., Klein S. Hyperacuity and amblyopia. Nature. 1982 Jul 15;298(5871):268–270. doi: 10.1038/298268a0. [DOI] [PubMed] [Google Scholar]
  15. Ray W. A., O'Day D. M. Statistical analysis of multi-eye data in ophthalmic research. Invest Ophthalmol Vis Sci. 1985 Aug;26(8):1186–1188. [PubMed] [Google Scholar]
  16. Shimojo S., Birch E. E., Gwiazda J., Held R. Development of vernier acuity in infants. Vision Res. 1984;24(7):721–728. doi: 10.1016/0042-6989(84)90213-x. [DOI] [PubMed] [Google Scholar]
  17. Shimojo S., Held R. Vernier acuity is less than grating acuity in 2- and 3-month-olds. Vision Res. 1987;27(1):77–86. doi: 10.1016/0042-6989(87)90144-1. [DOI] [PubMed] [Google Scholar]
  18. Teller D. Y., Morse R., Borton R., Regal D. Visual acuity for vertical and diagonal gratings in human infants. Vision Res. 1974 Dec;14(12):1433–1439. doi: 10.1016/0042-6989(74)90018-2. [DOI] [PubMed] [Google Scholar]
  19. Westheimer G. The spatial grain of the perifoveal visual field. Vision Res. 1982;22(1):157–162. doi: 10.1016/0042-6989(82)90177-8. [DOI] [PubMed] [Google Scholar]
  20. Westheimer G. The spatial sense of the eye. Proctor lecture. Invest Ophthalmol Vis Sci. 1979 Sep;18(9):893–912. [PubMed] [Google Scholar]

Articles from The British Journal of Ophthalmology are provided here courtesy of BMJ Publishing Group

RESOURCES