Slope estimates, standard errors (SE), p-values, and variance inflation factor (VIF) for a five-predictor variable model selected for predicting struvite relative supersaturation.

Variable Slope estimates Standard errors (SE) p-value Variance inflation factor (VIF)
Intercept −32.26 2.26 <0.001 0
pH 5.16 0.35 <0.001 1.49
Sodium −3.93 1.70 0.022 1.02
Magnesium 519 103.3 <0.001 1.91
Oxalate 1,278 518.3 0.014 1.92
Citrate −286 51.3 <0.001 1.59