Skip to main content
. 2023 Aug 7;11:1228257. doi: 10.3389/fped.2023.1228257

Table 4.

Univariate analysis of Clouclip M2 eye behavior, eye environment, and screening myopia in students.

Clouclip M2
Myopia Non-myopia Χ 2 P
Average total time for near work per day
 <180 min 19 13
 ≥180 min 143 37 6.072 0.014
Maximum time for single near work
 <60 min 42 23
 ≥60 min 120 27 7.242 0.007
Average distance of near work
 <30 cm 52 15
 ≥30 cm 110 35 0.078 0.780
Average total time for outdoor activities per day
 <90 min 118 26
 ≥90 min 44 24 7.616 0.006
Average outdoor exposure times
 <8 times 78 14
 ≥8 times 84 36 6.314 0.012
Daytime luminance
 <200 lux 96 21
 ≥200 lux 66 29 4.602 0.032
Nighttime luminance
 <125 lux 104 24
 ≥125 lux 58 26 4.190 0.041

P value indicates whether there is statistical difference in the behavior of each eye measured by Clouclip M2 between the myopia group and the non-myopia group.