Skip to main content
. 2023 Aug 21;14:5079. doi: 10.1038/s41467-023-40806-9

Table 1.

Photovoltaic parameters of D18:AQx-2, D18:AQx-6 and D18:AQx-8 based OSCs under the illumination of AM 1.5 G, 100 mW cm−2

Acceptors Voc
(V)
JSC
(mA cm−2)
JSCcal,b
(mA cm−2)
FF
(%)
PCE
(%)
Enrc
(eV)
Elossd
(eV)
AQx-2a

0.868

(0.869 ± 0.003)

26.1

(25.8 ± 0.2)

25.4

76.0

(75.6 ± 0.3)

17.2

(17.0 ± 0.11)

0.206 0.529
AQx-6a

0.892

(0.890 ± 0.002)

26.8

(26.7 ± 0.1)

25.5

77.8

(77.1 ± 0.5)

18.6

(18.3 ± 0.10)

0.198 0.518
AQx-8a

0.913

(0.909 ± 0.003)

24.7

(24.9 ± 0.1)

23.9

75.7

(75.0 ± 0.4)

17.1

(17.0 ± 0.05)

0.178 0.493
AQx-6e 0.874 26.7 79.1 18.4

aAverage values with standard deviation were obtained from 10 individual devices.

bThe calculated JSC values from the EQE curve.

cCalculated using eq. ∆Enr = −(kT/q)In(EQEEL).

dCalculated using eq. ∆Eloss = EgqVOC, in which Eg is determined the crossing point of absorption and emission.

eThe certified PCE obtained from National Institute of Metrology (NIM), Chain.