Comparison between the rate constants we measured and literature values. Specified uncertainties correspond to standard errors.
Temperature | k [M−2 s−1] × 104 | Literature values52 |
---|---|---|
60 °C | 3.32 ± 0.07 | 2.87, 3.03 |
70 °C | 5.00 ± 0.14 | 5.10, 5.15, 5.08 |
80 °C | 7.90 ± 0.30 | 7.77, 7.75 |
90 °C | 10.6 ± 0.40 | — |