Skip to main content
. 2023 Aug 4;14(33):8798–8809. doi: 10.1039/d3sc02082g

Comparison between the rate constants we measured and literature values. Specified uncertainties correspond to standard errors.

Temperature k [M−2 s−1] × 104 Literature values52
60 °C 3.32 ± 0.07 2.87, 3.03
70 °C 5.00 ± 0.14 5.10, 5.15, 5.08
80 °C 7.90 ± 0.30 7.77, 7.75
90 °C 10.6 ± 0.40