Table 2. Reference operating conditions and main characteristics available by the manufacturer of the LG Chem Resu10 48 V LIB 38 .
| Variable | Unit | Value |
|---|---|---|
| General | ||
| DC voltage operating range | V | 42.0~58.8 |
| Volume (exterior box) | m 3 | 0.05 |
| Weight | Kg | 75 |
| Average environmental temperature | °C | 20 |
| Depth of discharge | % | 80 |
| Energetic | ||
| Nominal energy / useful | kWh | 9.8 (25°C, 100% SOC) / 8.8 |
| Nominal power / maximum / peak (in 3 s) | kW | 3.3 / 5.0 / 7.0 |
| Nominal Capacity | Ah | 189 |
| Maximum Current | A | 119 at 42V |
| DC nominal Voltage | V | 51.8 |
| Cycles number (90% DOD, 25°C) | - | 6000 |
| Cycles number (80% DOD, 25°C) | - | 10000 |
| Environmental conditions | ||
| Cooling | - | Natural convection |
| Operating Temperature | °C | -10 a 45 |
| Optimal Operating Temperature | °C | 15 a 30 |
| Storage temperature | °C | -30 a 60 |
| Humidity | % | 5 a 95 (no condensation) |
| Altitude | m | < 2000 |