Skip to main content
. 2022 Oct 4;46(6):2080–2089. doi: 10.55730/1300-0527.3504

Table 1.

Kinetics parameters for the adsorption of phenanthrene and anthracene by the electrospun PCL membrane.

Experimental Pseudofirst-order model Pseudosecond-order model
qexp (μg/g) qe (μg/g) k1 (min−1) R 2 qe (μg/g) k2 (g.μg−1 min−1) R 2
Phe 560 ± 51 624.73 −0.00019 0.9934 649.35 0.000058 0.9658
Ant 173 ± 17 177.24 −0.00015 0.9990 215.05 0.000121 0.9150