Table 2. Fitted Parameters of the Two-Region Model for the Three Tracer Experiments Conducted for Each Columna.

Parameter C1
C2
C3
PV [-] 10 70 end 10 71 end 10 75 end
β [-] 0.455 ± 0.002 0.462 ± 0.001 0.606 ± 0.003 0.900 ± 0.006 0.996 ± 0.004 1.000 ± 0.000 0.907 ± 0.005 0.774 ± 0.005 0.805 ± 0.002
η [-] 0.443 ± 0.001 0.430 ± 0.001 0.377 ± 0.001 0.501 ± 0.003 0.499 ± 0.002 0.472 ± 0.003 0.431 ± 0.001 0.468 ± 0.001 0.444 ± 0.001
ηm [-] 0.202 ± 0.001 0.198 ± 0.001 0.228 ± 0.001 0.451 ± 0.004 0.498 ± 0.002 0.472 ± 0.003 0.391 ± 0.002 0.362 ± 0.003 0.357 ± 0.001
ηim [-] 0.241 ± 0.002 0.231 ± 0.001 0.148 ± 0.001 0.050 ± 0.005 0.002 ± 0.003 0.000 ± 0.004 0.040 ± 0.002 0.106 ± 0.003 0.087 ± 0.001
ω [day–1] 0.204 ± 0.003 0.190 ± 0.001 0.319 ± 0.006 0.023 ± 0.004 0.023 ± 0.023 0.046 ± 0.044 0.148 ± 0.015 0.788 ± 0.030 0.661 ± 0.012
α [cm] 0.767 ± 0.045 0.613 ± 0.022 0.231 ± 0.022 2.221 ± 0.088 1.645 ± 0.046 3.200 ± 0.083 0.294 ± 0.014 0.057 ± 0.008 0.087 ± 0.004
a

Values are reported with the 95% confidence interval calculated by CXTFIT.