BioMed168
|
385 & 405 |
600 μm x 600 μm channels |
Yes |
UV post cure (60 min at 50°C), soak in PBS for 24 h at 50 °C. High autofluorescence in DAPI channel (~320–385, 445/50). Very stable at high temperatures (120 °C). |
152
|
BioMed Amber V1168
|
n.r., likely 405 |
500 μm channels |
Yes |
UV post cure (10–30 min). Channels printed orthogonal to the light source. |
165
|
|
|
385 & 405 |
600 μm x 600 μm channels |
Yes |
UV post cure (20 min at 40°C), soak in PBS for 24 h at 50 °C. High autofluorescence in DAPI channel (~320–385, 445/50). Moderate autofluorescence in EGFP channel (470/40, 525/50). |
152
|
Clear 168
|
385 |
|
Yes |
UV post cure (6–30 min), baked, autoclaved. Minor visible damage from autoclaving |
169
|
|
n.r., likely 405 |
300 μm x 150 μm trenches |
No |
UV post cure (15 min), autoclaved. Did not survive autoclaving |
164
|
|
n.r. |
|
No |
|
159
|
|
n.r., likely 405 |
500 μm channels |
No |
UV post cure (10–30 min). Channels printed orthogonal to the light source. |
165
|
|
MiiCraft Clear 170
|
n.r. |
250 μm x 250 μm channels |
n.r. |
UV post cure (10 min) |
154
|
|
Dental LT Clear 168
|
385 |
|
Yes |
UV post cure (6 min), autoclaved |
169
|
Dental LT Clear 168
|
n.r., likely 405 |
300 μm x 150 μm trenches |
No |
UV post cure (15 min), autoclaved. Did not survive autoclaving |
164
|
Dental LT V1 168
|
n.r., likely 405 |
500 μm channels |
No |
UV post cure (10–30 min). Channels printed orthogonal to the light source. |
165
|
Dental SG 168
|
n.r., likely 405 |
300 μm x 150 μm trenches |
Yes (56 days) |
UV post cure (15 min), autoclaved |
164
|
|
Elastic 50A V1168
|
n.r., likely 405 |
500 μm channels |
No |
UV post cure (10–30 min). Channels printed orthogonal to the light source. |
165
|
|
Flexible 168
|
405 |
|
Yes |
UV post cure (6 min), autoclaved. Poor opacity. |
169
|
Flexible 80A V1168
|
n.r., likely 405 |
500 μm channels |
No |
UV post cure (10–30 min). Channels printed orthogonal to the light source. |
165
|
|
Fototec 7150 Clear 171
|
n.r., likely 354.7 |
|
Yes |
Extensive ethanol wash, air dry |
160
|
n.r., likely 354.7 |
|
No |
|
159
|
|
FREEPRINT ortho 385172
|
385 |
1 mm x 600 μm channels |
n.r. |
UV post cure |
74
|
|
GR173
|
n.r., likely 405 |
400 μm x 400 μm channels |
n.r. |
Sonication in ethanol (5 min), UV post cure (3 min) |
174
|
|
|
385 |
|
Yes |
UV post cure (6 min), autoclaved. Cell viability was lower than expected |
169
|
GR-10175
|
385 |
100 μm wide x 1.2 mm tall pillars |
n.r. |
UV post cure, baked. All channels were printed open-faced |
176
|
|
n.r. |
|
Yes |
UV post cure (7 min) |
156
|
|
405 |
354 μm channels |
Yes |
UV post cure (10–30 min), surface polishing |
177
|
|
|
385 |
|
Yes |
UV post cure (36 min), autoclaved |
169
|
High Temp168
|
n.r., likely 405 |
300 μm x 150 μm trenches |
Yes (56 days) |
UV post cure (15 min), autoclaved. High autofluorescence in the UV range (ex/em 355/455 nm). |
164
|
|
KeyOrtho IBT178
|
385 |
could not produce channels |
n.r. |
UV post cure. Not mechanically stable enough to produce channels |
74
|
|
|
385 |
200 μm microneedles, no channels |
Yes |
UV bake and post cure (60 min) |
166
|
MiiCraft BV-007A170
|
385 |
200 μm x 200 μm channels |
No |
UV post cure (1 min), soak in PBS for 24 h at 37 °C. Negligible autofluorescence. High heat (>50 °C) delaminated the material over time. |
152
|
|
Model V2168
|
n.r., likely 405 |
500 um channels |
No |
UV post cure (10–30 min). Channels printed orthogonal to the light source. |
165
|
|
PlasCLEAR179
|
385 |
1 mm x 600 μm channels |
n.r. |
IPA wash, UV post cure |
74
|
|
405 |
|
No |
|
177
|
|
Tough 2000 V1168
|
n.r., likely 405 |
500 μm channels |
No |
UV post cure (10–30 min). Channels printed orthogonal to the light source. |
165
|
|
VisiJet SL Clear 180
|
n.r
|
|
No |
|
159
|
|
Watershed XC11122181
|
n.r., likely 354.7 |
|
No |
|
159,177
|