Table 3. NLLS Analyses of the Nyquist Plots Reported in Figure 5 Recorded by EIS after CV (Potential between 1.5 and 4.3 V vs Li+/Li) for the Li–O2 Cells Using the Investigated GDLs as Cathodesa.
GDL | circuit | R1 [Ω] | R2 [Ω] | R1 + R2 [Ω] | χ2 |
---|---|---|---|---|---|
22BB | Re(R1Q1)(R2Q2)Qg | 7.4 ± 0.6 | 78.9 ± 0.8 | 86.3 ± 1.4 | 1 × 10–4 |
28BC | Re(R1Q1)(R2Q2)Qg | 36.0 ± 1.4 | 78.7 ± 1.6 | 115 ± 3 | 7 × 10–6 |
36BB | Re(R1Q1)(R2Q2)Qg | 17.8 ± 0.8 | 78.1 ± 0.9 | 95.9 ± 1.7 | 5 × 10–5 |
39BB | Re(R1Q1)(R2Q2)Qg | 7.1 ± 0.9 | 86.1 ± 1.1 | 93.2 ± 2.0 | 1 × 10–4 |