Table 2.
Prediction of measured glomerular filtration rate of the study patients (n=62)
| Variable’s | Unstandardized (β) | SE | Standardized (β) | P * |
|---|---|---|---|---|
| Serum creatinine | −13.41 | 4.05 | −0.40 | 0.002 |
| BUN | −0.73 | 0.25 | −0.35 | 0.006 |
| Constant | 90.90 | 5.38 | <0.001 |
*P <0.05 significant. Dependent variable: mGFR, multiple linear regression analysis used. Unadjusted R2=44.1%, adjusted R2=42.2%, one-way ANOVA (P <0.001). mGFR: Measured glomerular filtration rate, BUN: Blood urea nitrogen, SE: Standard error