Correlation between the mfVEP upper or lower-ring signal-to-noise ratio and each parameter in study participants

Parameters mfVEP upper ring SNR mfVEP lower ring SNR
Age (y) Correlation Coefficient -0.19 - 0.24
* P-value 0.230 0.130
SE (D) Correlation Coefficient - 0.07 - 0.05
* P-value 0.646 0.730
AL (mm) Correlation Coefficient - 0.34 - 0.06
* P-value 0.984 0.690
BCDVA (logMAR) Correlation Coefficient - 0.33 -0.36
* P-value 0.038 0.024
IOP (mmHg) Correlation Coefficient - 0.34 - 0.14
* P-value 0.030 0.370
VF, superior or inferior hemifield Correlation Coefficient + 0.34 + 0.55
* P-value 0.030 < 0.001
RNFLT, inferior or superior quadrant Correlation Coefficient + 0.51 + 0.70
* P-value < 0.001 < 0.001

Abbreviations: mfVEP, multifocal visual evoked potential; SNR, signal-to-noise ratio; y, years; SE, spherical equivalent; D, diopters; AL, axial length; mm, millimeters; BCDVA, best-corrected distance visual acuity; logMAR, the logarithm of the minimum angle of resolution; IOP, intraocular pressure; mmHg, millimeter of mercury; VF, visual field; RNFLT, retinal nerve fiber layer thickness.* Spearman correlation; P-value < 0.05 is shown in bold.