Skip to main content
. 2023 Aug 23;23:509. doi: 10.1186/s12877-023-04180-x

Table 4.

Sensitivity, specificity and diagnostic accuracy of ICOPE screening tool

Detailed IC assessment (IC domain impairment) Possible IC decline by ICOPE screening tool Sensitivity (%) Specificity (%) Diagnostic accuracy (%)
Assessment result Yes No
IC decline Yes 158 9 94.6 62.3 86.0
No 23 38
Locomotion Yes 108 29 78.8 93.4 84.6
No 6 85
Vitality Yes 20 19 51.3 94.7 87.3
No 10 179
Cognition Yes 39 0 100 55.6 63.2
No 84 105
Psychology Yes 27 10 73.0 72.3 72.4
No 53 138

Abbreviations: IC Intrinsic capacity, ICOPE Integrated care for older people