Abstract
Red blood cells of vertebrates have undergone evolutionary changes over time, leading to the diversification of morphological and mechanical properties of red blood cells (RBCs). Among the vertebrates, camelids have the most different RBC characteristics. As a result of adaptation to the desert environment, camelid RBCs can expand twice as much of their total volume in the case of rapid hydration yet are almost undeformable under mechanical stress. In this work, the mechanical and chemical differences in the RBC properties of the human and camelid species were examined using optical tweezers and Raman spectroscopy. We measured the deformability of camel and human RBCs at the single-cell level using optical tweezers. We found that the deformability index (DI) of the camel and the human RBCs were 0.024 ± 0.019 and 0.215 ± 0.061, respectively. To investigate the chemical properties of these cells, we measured the Raman spectra of the whole blood samples. The result of our study indicated that some of the Raman peaks observed on the camel’s blood spectrum were absent in the human blood’s spectrum, which further points to the difference in chemical contents of these two species’ RBCs.
Keywords: Red blood cells, Cell mechanics, Raman spectroscopy, Optical tweezers
Highlights
-
•
Mechanochemical differences between human and camel red blood cells were verified.
-
•
Camel red blood cells are one order of magnitude stiffer than human red blood cells quantified by dual-beam optical tweezers.
-
•
The protein/lipid content of the whole-blood samples differed from each other quantified by Raman spectroscopy.
0. Introduction
All the vertebrates, except Antarctic icefish, have circulating hemoglobin packed in red blood cells (RBCs) [1], [2]. These cells are responsible for oxygen transport for all modern vertebrates [3]. Among the vertebrates, RBCs vary in shape and size, ranging from (belongs to mouse deer) to (belongs to amphibian Amphiuma) in diameter [4]. The possible outcomes of such variations to RBCs’ mechanical functions are still under investigation [4]. Regarding such variations in RBCs’ shape, size, and deformability, there is no unique description of optimized RBC characteristics. The evolutionary mechanism at the molecular level that makes the difference between ellipsoidal- and discoidal-shaped RBCs is still under investigation [5].
Human RBCs are biconcave-shaped viscoelastic cells. Having an average diameter of about [6], they can deform through the small capillaries (with an inner diameter of less than ) without losing the cell functions in a certain amount of their lifetimes. Thereby, deformability is a crucial property for them to circulate through the vascular system effectively.
On the other hand, camelid RBCs are rigid and almost undeformable under mechanical stress [7], [8] and have an average diameter of 7.7 by with ellipsoidal geometry [9]. Rather, their ellipsoidal shape, makes them aligned with the stress field. Thereby, they can transverse through the circulatory system owing to their shape [7]. Yet, they can expand twice as much of their initial cell volume, [10], [11], [12], [13], which advantage camelids survive in the desert environment in the case of a large amount of hydration [9], [14], [15]. Such expandability and, at the same time, low deformability of these RBCs are related to the phospholipid composition of the cell membrane, which makes the membrane more fluid and the cells resistant to osmotic variations [14], [16], [17]. On the other hand, in the case of dehydration (water loss up to 27%), the fluidity of the camel blood is not affected since the camel erythrocytes make up a small amount of the blood content [18].
The structural differences between the camelid and human RBCs, in terms of osmotic stability, were formerly explained by the protein–lipid ratio and the protein organization of the cell membrane [19], [20], [21]. A study reported that the protein–lipid ratio for human RBC ghosts (which are dead cells without cytoplasmic structures) was measured as 1.25, while this value for camel RBCs was 3.0 [19]. Another study showed that the protein–lipid ratio was 1.2 and 3.7 for human and camel erythrocyte membranes, respectively [20]. The same study also indicated that the amount of membrane integral proteins was almost five times greater in camel cells [20]. In another study, high resistance to osmotic lysis of the camel erythrocytes was explained by changes in major integral proteins and the distribution of the glycoproteins in the cell membrane [22]. The other major difference between camel and human RBCs is the marginal band (MB). It is a circumferential bundle, made of microtubules that Camelid RBCs have whereas human RBCs do not [5], [23], [24]. It is probable functions were thought of as altering and perhaps maintaining cell shape [25].
Camel RBCs were investigated with varying techniques and modalities such as Klett photometer [26]. microcinematography [12]. flame photometer [27]. sonic irradiation [19]. gel electrophoresis [8], [20], [22]. viscometric techniques [7]. scanning electron microscope, [8] scanning and transmission electron microscopy [21]. chromatography [28]. blood count [9]. proteomics [17]. and rheometry [23]. These studies focused on osmotic behaviors, susceptibility to direct hemolysin of cobra venom, protein composition and organization of the membrane, the relationship between cell shape and membrane structure, homeostasis, and viscosity. To the best of our knowledge, up until now, camel red blood cells have never been investigated by optical tweezers.
Optical tweezers is a handy tool for life sciences, primarily in cell mechanics investigations. It enables fixation-free immobilization and manipulation of biological materials in the desired way. The physical principles behind this tool rely on the momentum conservation of light when it interacts with matter. The change in light’s momentum, due to the interaction with the particle of interest, forms optical forces on the particle [29], [30], [31], [32]. By controlling this force, it is possible to perform cell manipulation such as stretching. When an appropriate laser is used, it is possible to investigate cells in the living medium with no or a little amount of photodamage. By adding a second beam or splitting the original beam into two, a dual-beam optical tweezers system can be created where the cell mechanics is interrogated by stretching cells [33], [34], [35], [36]. Double-beam optical tweezers studies have two types of geometry: i) the beams counter-propagate [36], [37], [38] ii) both beams are in the axial direction and catch the cell from two ends [39], [40], [41], [42], [43]. Some of the studies investigated the deformation of red blood cells by optical tweezers for healthy cells [38], [39]. type 2 diabetes mellitus and diabetic retinopathy [37]. and radiation therapy applied cells [40].
As a fact, a change in the mechanical properties of the cells is closely related to the change in the chemical properties of these cells. One of the efficient ways to monitor this change is label-free Raman spectroscopy. This technique examines the vibrational transition energies of molecules due to laser-molecule interaction. The frequencies of the photons scattered from the sample differ from the illumination frequency as much as the molecular vibration frequency [44]. Previously, Raman spectroscopy was utilized to understand the link between mechanical and chemical structures of the red blood cells of some species but has never been applied to camel blood yet [45], [46], [47], [48], [49].
In this study, we approached the camel RBCs from the perspective of cell mechanics by measuring cell deformability. We applied direct mechanical stress with optical tweezers to an isolated RBC in order to test the RBC’s capacity to deform. By trapping the erythrocytes from the two ends and moving one of the traps with a certain speed, mechanical stress was created, and cell stretching was achieved. In addition, for label-free chemical analysis of the blood samples, we utilized Raman spectroscopy.
1. Materials and methods
1.1. Ethical statement
One healthy woman and two healthy men volunteered for this study. From each participant, informed consent was obtained, which was ethically approved by Bogazici University Science and Engineering Fields Human Research Ethics Committee (FMINAREK) with the ethical permission number 2022-05. Two healthy male single-humped dromedaries participated in this study. The ethical approval was obtained from Bogazici University Institutional Animal Experiments Local Ethics Committee (BUHADYEK) with permission number 2021-017. All the methods were carried out in accordance with the relevant guidelines and regulations. All the experimental protocols were approved by FMINAREK and BUHADYEK.
1.2. Blood collection
Human blood samples were drawn using a lancet needle from the participants’ fingertips and placed into an experiment tube containing PBS (Phosphate-buffered saline) and BSA (Bovine serum albumin) at room temperature. Camelid blood samples were taken by a veterinarian, contained in the EDTA tubes, and transported at 4 °C to the laboratory. All the measurements were completed on the same day of blood collection.
1.3. Sample preparation
For optical tweezers experiments, whole blood of 0.1 L was mixed with 1 mL PBS and 100 L BSA solution in a tube. 70 L of the prepared blood sample was placed onto the microscope slide, and BSA-dried cover glass was placed on top. The edges of the cover glass were sealed using nail polish. The BSA-dried cover glass was used to prevent RBCs from adhering to the cover glass. The BSA-dried cover glass was prepared by placing 40 L BSA on a cover glass and kept in an incubator at 45 °C for 10 min. The experiments were performed at room temperature. For the Raman spectral measurements, a droplet of whole blood in liquid form was measured on a glass microscope slide.
1.4. Experiment and analysis
The cell stretching experiments were performed using dual-beam Zeiss PALM Micro Tweezers with the laser of 1064 nm wavelength and the power (at the back focal plane) of 700 mW (350 mW or each trap) and, the camera Zeiss Axiocam 503 color D. We used 100 oil immersion objective (Objective EC “Plan-Neofluar” 100x/1.3 Oil Iris M27) with a numerical aperture of 1.3, and transmittance of about 50% at 1064 nm laser wavelength. In literature, the optical trapping power above 280 mW was reported to damage RBCs at 1064 nm wavelength [50]. Therefore, the maximum laser power available for the tweezer does not have a harmful effect on RBCs in the stretching experiments.
The determined cell stretching parameters (i.e. velocity and the direction of the trap movement, the power of the traps, and the duration of the experiment) were set on the user interface of the tweezers. When the experiment was started, the cell stretching was automatically performed by the tweezers with respect to the determined parameters. The stretching experiments were conducted without using microbeads. Therefore, trap stiffness could not be specified in these experiments [37]. All the measurements were done at the maximum available laser power since camel RBCs are stiff, they could be deformed only at that maximum laser power. Apart from this, the dependence of the deformability index on the trap power was formerly reported in our previous study [40]. It has a linear dependency on the trap power.
Before starting the stretching process, the optical traps (while off) were positioned on the two ends of the cell with a trap separation of (Fig. 1a). After the positioning procedure, the traps were activated and the cell aligned with the traps as shown in Fig. 2c with the arrow. Then, the experiment was started. During the stretching, one of the traps was moving with the defined velocity of 1 for 10 s, while the other was kept fixed in position. When the trap started to move, the RBC first stretched, and then after reaching the maximum stretched length, it escaped from the moving trap and became relaxed as demonstrated in Fig. 2 a1–a5.
Fig. 1.
(a) The single-cell stretching process by the optical tweezers, (b) Demonstration of whole blood sample measurement on the Raman spectroscopy setup. The red beam shows the laser light whereas, the orange beam indicates the Raman signal from the sample. Abbreviations: DM (Dichroic Mirror), REF (Raman Edge Filter). (For interpretation of the references to color in this figure legend, the reader is referred to the web version of this article.)
Fig. 2.
(a1–4) Top view of stretching and relaxation processes of a human (top row) and, (b1–4) a camel (bottom row) RBCs. Stretching speed was set to 1 and the experiment duration was 10 s. The calculated Feret diameters were labeled on the RBCs in each frame. (c) The unmarked cells were suspended camel RBCs in the solution, and the marked cell was the camel RBC in the optical trap.
Feret diameter is a commonly used method for the analysis of cell size [51], [52]. We used the maximum Feret diameter function of Matlab [53] to calculate the long-axial diameter of the erythrocytes. Therefore, the deformability index (DI) [37] was calculated using the following equation:
| (1) |
where, is the initial (unstretched) length, is the maximum stretched length of the RBC.
Raman spectral measurements were performed on a droplet of whole-blood samples on a glass microscope slide. In the experimental setup, an optical microscope with 10 objective (Nikon Ti, Tokyo, Japan, NA=0.25), a Raman spectrometer (Ocean QE Pro, Orlando FL, USA), and a continuous laser source with a wavelength of 785 nm and a power of 500 mW (Laser Glow, Toronto, Canada) were utilized (Fig. 1b). We directed the laser beam to the sample via 4-f configuration using two lenses and a mirror to pump the ground vibrational state of the molecules in the blood. The Raman scattered photons (the orange beam in Fig. 1b were selected by the dichroic mirror (Thorlabs DMSP 805, New Jersey, USA) and, were directed to the spectrometer through a lens (f=50 mm) after going through the two sequential Raman edge filters (Thorlabs FELH0800) which were used to eliminate the Rayleigh scattered photons. The Raman spectra were recorded using the commercial software provided by OceanView. The pre-processing of the data includes calibration, baseline subtraction, and vector normalization. Calibration was done using polystyrene beads as a reference Raman spectrum [54]. In the fluorescence baseline removal, a polynomial spline fit curve of the selected wavenumber, was subtracted from each spectrum. Finally, a vector normalization method (also called L2 normalization) was applied to the spectra for better comparison. All these steps were performed on Matlab [53].
2. Results and discussion
In this study, we measured 206 human and 159 camel RBCs using optical tweezers. The single stretching–relaxation process of an individual RBC can be viewed in Fig. 2.
The kernel fit to the data shows a comparison of the initial (), and the maximum () stretched lengths of the cells. Kernel bandwidths for the camel group were found as 0.2964 and 0.3130, and for the human group, they were calculated as 0.2304 and 0.2496, respectively. In the camel group, the separation of the L and L curves was very small whereas, for the human group, these two curves were dramatically differentiated from each other (Figs. 3a and b). This result supports the current literature, which points out that camel RBCs are less deformable than human RBCs.
Fig. 3.
Normal kernel distribution of initial () and maximum () stretched RBC cell sizes with the corresponding bandwidths were: (a) for the camel group 0.2964 and 0.3130 and, (b) for the human group 0.2304 and 0.2496 c) The violin graph of the DI with the mean values and the standard deviations for camel and human groups were calculated as 0.024±0.019 and 0.2150.061, respectively. The result of the t-test was .
In Fig. 3c, we demonstrated the violin graph of the deformability index of the RBCs calculated using Eq. (1). The graph revealed the mean DI of the camel and human groups with the standard deviations as 0.024 ± 0.019 and 0.215 ± 0.061, respectively. This result showed that camel RBCs are almost one order of magnitude less deformable than human RBCs. The student’s t-test was applied to the DI data and the difference was found statistically significant ().
In our results, we observed that the majority of the camel RBCs in our data set became shorter after escaping one of the optical traps as seen in Fig. 2 b5. Such behavior could be related to the buckling or shortening of MB in camel RBCs. Nedelec et al. [55] simulated the dynamics of MB in blood platelets, for 25 species. According to their findings, MB of blood platelets, in various species, shortens or buckles depending on the strength of the applied tension. In our experiments, the contracted camel RBCs’ behaviors after stretching may be indicative of a change in MB in camel RBCs.
To obtain chemical information about the two species’ blood, we measured the Raman spectra of the whole blood. We repeated the measurements with the Raman spectrometer ten times for each blood sample to decrease the measurement error. Fig. 4 clearly shows the difference between the average Raman spectra of both species. To quantify the difference and reveal the sub-components of the important Raman peaks, we applied a Gaussian curve-fitting on the spectra. The main differences between the two species were found in the reported Raman shift values in Table 1 and Fig. 5.
Fig. 4.
The Raman spectra of the two groups indicated dramatic differences in intensities at three wavenumbers: 540 cm−1, 714 cm−1 and 1080 cm−1. The bands, 838 cm−1 and 945 cm−1, were found as absent on the human spectrum, while these bands were present on the camel spectrum.
Table 1.
The Raman band assignments of human and camel blood.
| Raman Shift | Normalized Raman Intensity (a.u.) |
Assignment | |
|---|---|---|---|
| Human | Camel | ||
| 540 | 0.0022 ± 0.0078 | 0.0042 ± 0.0009 | S—S [54], [56] |
| 714 | 0.0052 ± 0.0007 | 0.0277 ± 0.0031 | C—N (phospholipid membrane) [57] |
| 838 | absent | 0.0303 ± 0.0017 | tyrosine [58], [59], vibrations of amine groups [60] |
| 945 | absent | 0.0144 ± 0.0034 | skeletal modes (polysaccharides, amylose) [56], [61] |
| 998 | 0.0264 ± 0.0026 | 0.0396 ± 0.0028 | [62] |
| 1080 | 0.0074 ± 0.0026 | 0.0190 ± 0.0043 | ,phospholipids [62], [63] |
| 1123 | 0.0047 ± 0.0025 | 0.0300 ± 0.0031 | (pyr half-ring)[62] |
| 1220 | 0.0254 ± 0.0061 | 0.0388 ± 0.0027 | ,amide III [62] |
| 1305 | 0.0493 ± 0.0009 | 0.0338 ± 0.0049 | [62] |
| 1368 | 0.0920 ± 0.0008 | 0.0854 ± 0.0119 | heme, (pyr half-ring)[62] |
| 1439 | 0.0161 ± 0.0006 | 0.0273 ± 0.0078 | [64] |
| 1557 | 0.0326 ± 0.0058 | 0.0343 ± 0.0023 | [62] |
| 1650 | 0.0214 ± 0.0020 | 0.0094 ± 0.0020 | (C C) amide I, amide I absorption [65] |
Fig. 5.
The bar graph shows the selected peak Raman intensities after the band component analysis. These peak intensities were correlated to the amount of lipid and protein compositions; 714 cm−1 and 1080 cm−1 phospholipids, 1220 cm−1 amide III, 1305 cm−1 and 1443 cm−1 lipids, and 1650 cm−1 amide I.
According to Fig. 4, the difference in peak intensities at 540 cm−1 band of the two species was observed and this band was assigned to S–S signal. 540 cm−1 peak was reported as the sign of integral proteins of the cell membrane [54], [56]. The amount of the integral proteins was reported to be five times greater in camel erythrocytes compared to human erythrocytes [20]. However, we observed that the spectral intensity of the 540 cm−1 band of the camels was twice as much of humans. The Raman signal at 714 cm−1 was assigned to phospholipid membranes [57]. The current literature shows that RBCs membrane structures are different in human and camel groups [19], [20], [21]. Our data indicated that Raman intensity at 714 cm−1 was higher in camels than in humans. Such a difference may indicate the structural difference between these two cell types. The two wavenumbers in the spectrum, 838 cm−1, and 945 cm−1, were absent for the human group, while these were Raman-active for the camel group. The band 838 cm−1 was assigned to tyrosine [58], [59] and deformative vibrations of amine groups. The presence of the Raman signal at this peak for camels compared to humans remained inconclusive. The band, 945 cm−1, was assigned to polysaccharides and amylose [56], [61]. It was reported that camels have high blood glucose levels [66]. In addition, the same study compared the amylase levels in camels as monogastric animals and humans as ruminant animals and found that intestinal amylase level is much higher in camels. Therefore, the main difference observed in 945 cm−1 for the two groups may stem from whether being a monogastric or ruminant animal [66]. The Raman intensities at 1368 cm−1 of the two groups [67], which were assigned to blood hemoglobin concentration level, were found very close to each other.
3. Conclusion
Cells are complex systems such that mechanical and chemical stimulations drive each other. In such complex and crowded lipid/protein compositions, it is challenging to attribute cells’ mechanical behaviors to specific lipid/protein types. An alternative way to understand cell mechanics is to deform cells and observe their mechanical responses.
Red blood cells are very simple-structured among the other cell types, they vary in shape, size, and the presence and absence of some structures such as marginal bands and nuclei, among vertebrates. In such variations, their function is surprisingly almost the same, i.e. oxygen transport. Therefore, there is no unique description of red blood cell mechanics. Especially, mammalian RBCs are a good model to study cell mechanics, since they lack nuclei and organelles in their mature states so they are easy to deform.
The aim of this work was to investigate the most different cell types among vertebrates, i.e. camel erythrocytes in comparison to human erythrocytes. Examining the deformation characteristics of the cells using optical tweezers gave some results such that the deformability of camel and human RBCs was found as one order of magnitude apart from each other. In addition, we showed that the mechanical stress on camel RBCs caused the cells to become shorter. Such behavior may be a result of buckling or shortening of MB under mechanical stress.
On the other hand, the whole blood analysis of the two species’ Raman spectral data shed some light on the chemical content of these two types of RBCs, which are closely related to the mechanical features. However, we could not conduct single-cell Raman spectral measurements due to our technical limitations. Instead, we measured the Raman spectrum of the whole blood. Nevertheless, the results, we gathered from the measurements with optical tweezers and Raman spectroscopy, may be an indicator of mechanochemical differences between these two species’ RBCs.
The evolutionary mechanism at the molecular level for variation in RBC shapes is still under investigation. Especially, the cytoskeleton itself is a structure that has not yet been fully understood. In this respect, efforts for the characterization of the cytoskeleton of camelid red blood cells may unveil the evolutionary mechanisms that diverge RBC shapes. Furthermore, understanding the cytoskeleton and its functions in diseases such as cancer and diabetes mellitus has the potential to lead to new diagnostic and treatment methods in the future.
Future efforts can explore the comparative nature of human and camel RBCs by performing single-cell Raman measurements as a complementary measurement to single-cell deformation experiments to obtain more satisfactory results.
CRediT authorship contribution statement
Tuna Pesen: Conducted the experiment(s), Analyzed the results, Wrote the analysis codes, Created the figures, Wrote the manuscript, Reviewed the manuscript. Mete Haydaroglu: Conducted the experiment(s), Analyzed the results, Created the figures, Reviewed the manuscript. Simal Capar: Conducted the experiment(s), Analyzed the results, Reviewed the manuscript. Ugur Parlatan: Conceived the experiment(s), Wrote the manuscript, Reviewed the manuscript. Mehmet Burcin Unlu: Conceived the experiment(s), Reviewed the manuscript.
Declaration of competing interest
The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Acknowledgments
This study was supported by a grant from the Directorate of Presidential Strategy and Budget of Turkey (Project Number: 2009K120520) and by a grant from Bogazici University Higher Education Council Scientific Research Projects (Project Number: 18143D).
References
- 1.Holeton G.F. Oxygen uptake and circulation by a hemoglobinless Antarctic fish (Chaenocephalus aceratus lonnberg) compared with three red-blooded Antartic fish. Compar. Biochem. Physiol. 1970;34(2):457–471. doi: 10.1016/0010-406x(70)90185-4. [DOI] [PubMed] [Google Scholar]
- 2.Sidell B.D., O’Brien K.M. When bad things happen to good fish: the loss of hemoglobin and myoglobin expression in Antarctic icefishes. J. Exp. Biol. 2006;209(10):1791–1802. doi: 10.1242/jeb.02091. [DOI] [PubMed] [Google Scholar]
- 3.Anderson H.L., Brodsky I.E., Mangalmurti N.S. The evolving erythrocyte: red blood cells as modulators of innate immunity. J. Immunol. 2018;201(5):1343–1351. doi: 10.4049/jimmunol.1800565. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Snyder G.K., Sheafor B.A. Red blood cells: centerpiece in the evolution of the vertebrate circulatory system. Am. Zool. 1999;39(2):189–198. [Google Scholar]
- 5.Chen Y., Miyazono K., Otsuka Y., Kanamori M., Yamashita A., Arashiki N., Matsumoto T., Takada K., Sato K., Mohandas N., et al. Membrane skeleton hyperstability due to a novel alternatively spliced 4.1 R can account for ellipsoidal camelid red cells with decreased deformability. J. Biol. Chem. 2023 doi: 10.1016/j.jbc.2023.102877. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Ponder E. The measurement of the diameter of erythrocytes. V.—The relation of the diameter to the thickness. Quart. J. Exper. Physiol. Transl. Integr. 1930;20(1):29–39. [Google Scholar]
- 7.Smith J.E., Mohandas N., Shohet S.B. Variability in erythrocyte deformability among various mammals. Am. J. Physiol.-Heart Circul. Physiol. 1979;236(5):H725–H730. doi: 10.1152/ajpheart.1979.236.5.H725. [DOI] [PubMed] [Google Scholar]
- 8.Omorphos S., Hawkey C.M., Rice-Evans C. The elliptocyte: a study of the relationship between cell shape and membrane structure using the camelid erythrocyte as a model. Compar. Biochem. Physiol. B, Compar. Biochem. 1989;94(4):789–795. doi: 10.1016/0305-0491(89)90167-3. [DOI] [PubMed] [Google Scholar]
- 9.Yagil R., Sod-Moriah U., Meyerstein N. Dehydration and camel blood. II. Shape, size, and concentration of red blood cells. Am. J. Physiol.-Legacy Content. 1974;226(2):301–304. doi: 10.1152/ajplegacy.1974.226.2.301. [DOI] [PubMed] [Google Scholar]
- 10.Perk K. The camel’s erythrocyte. Nature. 1963;200(4903):272–273. doi: 10.1038/200272a0. [DOI] [PubMed] [Google Scholar]
- 11.Perk K., Frei Y., Herz A., et al. Osmotic fragility of red blood cells of young and mature domestic and laboratory animals. Am. J. Veterinary Res. 1964;25:1241–1248. [PubMed] [Google Scholar]
- 12.Perk K. Osmotic hemolysis of the camel’s erythrocytes. I. A microcinematographic study. J. Experim. Zool. 1966;163(3):241–246. [Google Scholar]
- 13.Fowler M. John Wiley & Sons; 2011. Medicine and Surgery of Camelids. [Google Scholar]
- 14.Hoter A., Rizk S., Naim H.Y. Cellular and molecular adaptation of arabian camel to heat stress. Front. Genet. 2019;10:588. doi: 10.3389/fgene.2019.00588. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Macfarlane W., Morris R., Howard B., et al. Turn-over and distribution of water in desert camels, sheep, cattle and kangaroos. Nature. 1963;197:270–271. [Google Scholar]
- 16.Warda M., Zeisig R., et al. Phospholipid-and fatty acid-composition in the erythrocyte membrane of the one-humped camel (camelus dromedarius) and its influence on vesicle properties prepared from these lipids. Deutsche Tieraerztliche Wochenschrift. 2000;107(9):368–373. [PubMed] [Google Scholar]
- 17.Warda M., Prince A., Kim H.K., Khafaga N., Scholkamy T., Linhardt R.J., Jin H. Proteomics of old world camelid (Camelus dromedarius): Better understanding the interplay between homeostasis and desert environment. J. Adv. Res. 2014;5(2):219–242. doi: 10.1016/j.jare.2013.03.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Long C.A. Evolution of function and form in camelid erythrocytes. Biophys. Bioeng. 2007 [Google Scholar]
- 19.Livne A., Kuiper P.J. Unique properties of the camel erythrocyte membrane. Biochim. Biophys. Acta (BBA)-Biomembranes. 1973;318(1):41–49. doi: 10.1016/0005-2736(73)90334-9. [DOI] [PubMed] [Google Scholar]
- 20.Eitan A., Aloni B., Livne A. Unique properties of the camel erythrocyte membrane: II. Organization of membrane proteins. Biochim. Biophys. Acta (BBA)-Biomembranes. 1976;426(4):647–658. doi: 10.1016/0005-2736(76)90129-2. [DOI] [PubMed] [Google Scholar]
- 21.Khodadad J.K., Weinstein R.S. The band 3-rich membrane of llama erythrocytes: studies on cell shape and the organization of membrane proteins. J. Membrane Biol. 1983;72(3):161–171. doi: 10.1007/BF01870583. [DOI] [PubMed] [Google Scholar]
- 22.Ralston G.B. Proteins of the camel erythrocyte membrane. Biochim. Biophys. Acta (BBA)-Biomembranes. 1975;401(1):83–94. doi: 10.1016/0005-2736(75)90343-0. [DOI] [PubMed] [Google Scholar]
- 23.Windberger U., Auer R., Seltenhammer M., Mach G., Skidmore J.A. Near-Newtonian blood behavior–Is it good to be a camel? Front. Physiol. 2019;10:906. doi: 10.3389/fphys.2019.00906. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Goniakowska-Witalinska L., Witalinski W. Evidence for a correlation between the number of marginal band microtubules and the size of vertebrate erthrocytes. J. Cell Sci. 1976;22(2):397–401. doi: 10.1242/jcs.22.2.397. [DOI] [PubMed] [Google Scholar]
- 25.Cohen W.D., Terwilliger N.B. Marginal bands in camel erythrocytes. J. Cell Sci. 1979;36(1):97–107. doi: 10.1242/jcs.36.1.97. [DOI] [PubMed] [Google Scholar]
- 26.Condrea E., Mammon Z., Aloof S., De Vries A. Susceptibility of erythrocytes of various animal species to the hemolytic and phospholipid splitting action of snake venom. Biochim. Biophys. Acta (BBA)-Special. Section Lipids Related Subjects. 1964;84(4):365–375. doi: 10.1016/0926-6542(64)90001-0. [DOI] [PubMed] [Google Scholar]
- 27.Joshua H., Ishay J. The haemolytic properties of the Oriental hornet venom. Acta Pharmacol. Toxicol. 1973;33(1):42–52. doi: 10.1111/j.1600-0773.1973.tb01505.x. [DOI] [PubMed] [Google Scholar]
- 28.Turner J.C., Anderson H.M., Gandal C.P. Comparative liberation of bound phosphatides from red cells of man, ox, and camel. Proc. Soc. Experim. Biol. Med. 1958;99(3):547–550. doi: 10.3181/00379727-99-24415. [DOI] [PubMed] [Google Scholar]
- 29.Ashkin A. Acceleration and trapping of particles by radiation pressure. Phys. Rev. Lett. 1970;24(4):156. [Google Scholar]
- 30.Ashkin A., Dziedzic J.M., Bjorkholm J.E., Chu S. Observation of a single-beam gradient force optical trap for dielectric particles. Opt. Lett. 1986;11(5):288–290. doi: 10.1364/ol.11.000288. [DOI] [PubMed] [Google Scholar]
- 31.Ashkin A., Dziedzic J.M., Yamane T. Optical trapping and manipulation of single cells using infrared laser beams. Nature. 1987;330(6150):769–771. doi: 10.1038/330769a0. [DOI] [PubMed] [Google Scholar]
- 32.Gieseler J., Gomez-Solano J.R., Magazzù A., Castillo I.P., García L.P., Gironella-Torrent M., Viader-Godoy X., Ritort F., Pesce G., Arzola A.V., et al. Optical tweezers—from calibration to applications: a tutorial. Adv. Opt. Photon. 2021;13(1):74–241. [Google Scholar]
- 33.McCauley M.J., Williams M.C. Mechanisms of DNA binding determined in optical tweezers experiments. Biopolym. Original Res. Biomol. 2007;85(2):154–168. doi: 10.1002/bip.20622. [DOI] [PubMed] [Google Scholar]
- 34.Lincoln B., Wottawah F., Schinkinger S., Ebert S., Guck J. High-throughput rheological measurements with an optical stretcher. Methods Cell Biol. 2007;83:397–423. doi: 10.1016/S0091-679X(07)83017-2. [DOI] [PubMed] [Google Scholar]
- 35.Mills J., Qie L., Dao M., Lim C., Suresh S. Nonlinear elastic and viscoelastic deformation of the human red blood cell with optical tweezers. Molecul. Cellular Biomech. 2004;1(3):169. [PubMed] [Google Scholar]
- 36.Guck J., Ananthakrishnan R., Mahmood H., Moon T.J., Cunningham C.C., Käs J. The optical stretcher: a novel laser tool to micromanipulate cells. Biophys. J. 2001;81(2):767–784. doi: 10.1016/S0006-3495(01)75740-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Agrawal R., Smart T., Nobre-Cardoso J., Richards C., Bhatnagar R., Tufail A., Shima D., Jones P.H., Pavesio C. Assessment of red blood cell deformability in type 2 diabetes mellitus and diabetic retinopathy by dual optical tweezers stretching technique. Sci. Rep. 2016;6(1):1–12. doi: 10.1038/srep15873. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Rancourt-Grenier S., Wei M.-T., Bai J.-J., Chiou A., Bareil P.P., Duval P.-L., Sheng Y. Dynamic deformation of red blood cell in dual-trap optical tweezers. Opt. Express. 2010;18(10):10462–10472. doi: 10.1364/OE.18.010462. [DOI] [PubMed] [Google Scholar]
- 39.Bareil P.B., Sheng Y., Chen Y.-Q., Chiou A. Calculation of spherical red blood cell deformation in a dual-beam optical stretcher. Opt. Express. 2007;15(24):16029–16034. doi: 10.1364/oe.15.016029. [DOI] [PubMed] [Google Scholar]
- 40.Inanc M.T., Demirkan I., Ceylan C., Ozkan A., Gundogdu O., Goreke U., Gurkan U.A., Unlu M.B. Quantifying the influences of radiation therapy on deformability of human red blood cells by dual-beam optical tweezers. RSC Adv. 2021;11(26):15519–15527. doi: 10.1039/d1ra01948a. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Jess P., Garcés-Chávez V., Smith D., Mazilu M., Paterson L., Riches A., Herrington C., Sibbett W., Dholakia K. Dual beam fibre trap for Raman microspectroscopy of single cells. Opt. Express. 2006;14(12):5779–5791. doi: 10.1364/oe.14.005779. [DOI] [PubMed] [Google Scholar]
- 42.Sehgal H., Aggarwal T., Salapaka M. 2007 American Control Conference. IEEE; 2007. Characterization of dual beam optical tweezers system using a novel detection approach; pp. 4234–4239. [Google Scholar]
- 43.Ott D., Reihani S.N.S., Oddershede L.B. Crosstalk elimination in the detection of dual-beam optical tweezers by spatial filtering. Rev. Sci. Instrum. 2014;85(5) doi: 10.1063/1.4878261. [DOI] [PubMed] [Google Scholar]
- 44.Raman C.V., Krishnan K.S. A new type of secondary radiation. Nature. 1928;121(3048):501–502. [Google Scholar]
- 45.Rao S., Bálint Š., Cossins B., Guallar V., Petrov D. Raman study of mechanically induced oxygenation state transition of red blood cells using optical tweezers. Biophys. J. 2009;96(1):209–216. doi: 10.1529/biophysj.108.139097. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Wood B.R., Hammer L., McNaughton D. Resonance Raman spectroscopy provides evidence of heme ordering within the functional erythrocyte. Vib. Spectrosc. 2005;38(1–2):71–78. [Google Scholar]
- 47.Raj S., Wojdyla M., Sanchez M.M., Petrov D. Biophotonics: Photonic Solutions for Better Health Care III, vol. 8427. International Society for Optics and Photonics; 2012. Force and Raman spectroscopy of single red blood cell. [Google Scholar]
- 48.Liu R., Mao Z., Matthews D.L., Li C.-S., Chan J.W., Satake N. Novel single-cell functional analysis of red blood cells using laser tweezers Raman spectroscopy: application for sickle cell disease. Experim. Hematol. 2013;41(7):656–661. doi: 10.1016/j.exphem.2013.02.012. [DOI] [PubMed] [Google Scholar]
- 49.Deng J., Wei Q., Zhang M., Wang Y., Li Y. Study of the effect of alcohol on single human red blood cells using near-infrared laser tweezers Raman spectroscopy. J. Raman Spectrosc. 2005;36(3):257–261. [Google Scholar]
- 50.Chowdhury A., Waghmare D., Dasgupta R., Majumder S.K. Red blood cell membrane damage by light-induced thermal gradient under optical trap. J. Biophotonics. 2018;11(8) doi: 10.1002/jbio.201700222. [DOI] [PubMed] [Google Scholar]
- 51.Feret L. Eidgen. Materialprüfungsanstalt ad Eidgen. Technischen Hochschule; 1930. La Grosseur Des Grains Des MatiÈRes PulvÉRulentes. [Google Scholar]
- 52.Pons M.-N., Vivier H., Delcour V., Authelin J.-R., Paillères-Hubert L. Morphological analysis of pharmaceutical powders. Powder Technol. 2002;128(2–3):276–286. [Google Scholar]
- 53.2021. MATLAB version 9.10.0.1613233 (R2021a) [Google Scholar]
- 54.Nakamoto K. John Wiley & Sons; 2009. Infrared and Raman Spectra of Inorganic and Coordination Compounds, Part B: Applications in Coordination, Organometallic, and Bioinorganic Chemistry. [Google Scholar]
- 55.Dmitrieff S., Alsina A., Mathur A., Nédélec F.J. Balance of microtubule stiffness and cortical tension determines the size of blood cells with marginal band across species. Proc. Natl. Acad. Sci. 2017;114(17):4418–4423. doi: 10.1073/pnas.1618041114. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56.Wesełucha-Birczyńska A., Kozicki M., Czepiel J., Łabanowska M., Nowak P., Kowalczyk G., Kurdziel M., Birczyńska M., Biesiada G., Mach T., et al. Human erythrocytes analyzed by generalized 2D Raman correlation spectroscopy. J. Mol. Struct. 2014;1069:305–312. [Google Scholar]
- 57.Stone N., Kendall C., Smith J., Crow P., Barr H. Raman spectroscopy for identification of epithelial cancers. Faraday Discuss. 2004;126:141–157. doi: 10.1039/b304992b. [DOI] [PubMed] [Google Scholar]
- 58.Naseer K., Amin A., Saleem M., Qazi J. Raman spectroscopy based differentiation of typhoid and dengue fever in infected human sera. Spectrochim. Acta Part A Mol. Biomol. Spectrosc. 2019;206:197–201. doi: 10.1016/j.saa.2018.08.008. [DOI] [PubMed] [Google Scholar]
- 59.Siamwiza M.N., Lord R.C., Chen M.C., Takamatsu T., Harada I., Matsuura H., Shimanouchi T. Interpretation of the doublet at 850 and 830 cm-1 in the Raman spectra of tyrosyl residues in proteins and certain model compounds. Biochemistry. 1975;14(22):4870–4876. doi: 10.1021/bi00693a014. [DOI] [PubMed] [Google Scholar]
- 60.Naumann D. Infrared Spectroscopy: New Tool in Medicine, vol. 3257. SPIE; 1998. Infrared and NIR Raman spectroscopy in medical microbiology; pp. 245–257. [Google Scholar]
- 61.Shetty G., Kendall C., Shepherd N., Stone N., Barr H. Raman spectroscopy: elucidation of biochemical changes in carcinogenesis of oesophagus. Br. J. Cancer. 2006;94(10):1460–1464. doi: 10.1038/sj.bjc.6603102. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 62.Wood B.R., McNaughton D. Raman excitation wavelength investigation of single red blood cells in vivo. J. Raman Spectrosc. 2002;33(7):517–523. [Google Scholar]
- 63.Tfaili S., Gobinet C., Josse G., Angiboust J.-F., Manfait M., Piot O. Confocal Raman microspectroscopy for skin characterization: a comparative study between human skin and pig skin. Analyst. 2012;137(16):3673–3682. doi: 10.1039/c2an16292j. [DOI] [PubMed] [Google Scholar]
- 64.Atkins C.G., Buckley K., Blades M.W., Turner R.F. Raman spectroscopy of blood and blood components. Appl. Spectrosc. 2017;71(5):767–793. doi: 10.1177/0003702816686593. [DOI] [PubMed] [Google Scholar]
- 65.Malini R., Venkatakrishna K., Kurien J., M. Pai K., Rao L., Kartha V., Krishna C.M. Discrimination of normal, inflammatory, premalignant, and malignant oral tissue: a Raman spectroscopy study. Biopolym. Original Res. Biomol. 2006;81(3):179–193. doi: 10.1002/bip.20398. [DOI] [PubMed] [Google Scholar]
- 66.Osman A.M., El Khatim M.M.S. Polysaccharidases of the camel (Camelus dromedarius) intestine and pancreas. Compar. Biochem. Physiol. Part A: Physiol. 1981;69(3):429–436. [Google Scholar]
- 67.Virkler K., Lednev I.K. Raman spectroscopic signature of blood and its potential application to forensic body fluid identification. Anal. Bioanal. Chem. 2010;396(1):525–534. doi: 10.1007/s00216-009-3207-9. [DOI] [PubMed] [Google Scholar]