Skip to main content
. 2023 Jun 7;24(9):e14054. doi: 10.1002/acm2.14054

TABLE 1.

Volumetric modulated arc therapy (VMAT) field arrangement parameters.

Arc range (°) Collimator angle (°)

Jaw positions

(X1, X2, Y1, Y2)

Plan A – 4 arc

50 – 181

181 – 50

50 – 181

181 – 50

355.0

5.0

90.0

90.0

10.0, 4.5, 9.1, 9.1

4.5, 10.0, 9.1, 9.1

4.0, 8.8, 9.6, 9.5

8.7, 4.0, 9.6, 9.5

Plan B – 5 arc

300 – 60

60 – 300

330 – 210

210 – 330

300 – 60

355.0

5.0

355.0

5.0

90.0

9.9, 4.6, 9.0, 9.1

4.0, 10.5, 9.1, 9.0

9.9, 4.6, 9.0, 9.0

4.0, 10.5, 9.0, 9.1

2.0, 8.8, 9.9, 9.2

Plan C – 6 arc bilat

50 – 215

215 – 50

155 – 310

310 – 155

155 – 215

215 – 155

350.0

10.0

355.0

5.0

90.0

90.0

12.5, 3.5, 10.5, 10.5

3.5, 12.5, 10.5, 10.5

11.0, 5.0, 10.5, 10.5

5.0, 11.0, 10.5, 10.5

10.0, 6.0, 16.5, 16.5

6.0, 10.0, 16.5, 16.5