Skip to main content
. 2023 Aug 9;13(4):638–649. doi: 10.21037/cdt-23-54

Table 3. Cardiac catheterization data.

Serial The stented coronary artery Approach Stent type Stent diameter (mm) Stent length (mm) Procedure duration (minutes) Fluoroscopy time (minutes) Contrast (mL/kg)
1 LMCA Hybrid DES 2.5 8 360 40 2.5
2 RCA Femoral DES 2.25 12 105 29 10
3 LMCA Femoral Bio-absorbable 3 10 65 27 1.8
4 LMCA Femoral DES 2.25 8 100 28 4
5 LMCA Hybrid DES 2.5 8 120 25 3
6 LMCA and RCA Hybrid DES 2.25 18 180 40 6.5
7 Circumflex Femoral DES 2.5 12 280 60 12
8 LMCA Femoral DES 2.5 8 360 58 9
9 RCA Femoral BMS 2.5 15 90 24 4.4
10* RCA Femoral DES 3.5 12 80 27 1.5
11 RCA Femoral DES 3 22 80 21 4

*, 3 months after RCA stenting, she underwent LMCA, and LAD artery stenting using a DES stent (3 mm × 22 mm). The procedural duration was 80 min, and the fluoroscopy time was 21 min. She received a contrast volume of 4 mL/kg. She was discharged home the next day after the procedure. LMCA, left main coronary artery; DES, drug-eluting stent; RCA, right coronary artery; BMS, bare metal stent; LAD, left anterior descending artery.