Skip to main content
. 2023 Jan 25;20(1):016028. doi: 10.1088/1741-2552/acae0d

Table 2.

Comparison between measured and modeled inductances for two different experimental rat TMS coils with and without the magnetic core. M3 Silicon steel (material #2) was modeled.

Coil A: 2 layers of windings Coil B: 3 layers of windings
20+20 turns 20+20+6 turns
Inductance, µH No core With core No core With core
Measured 7.0 40.0 8.5 50.0
Modeled 7.0 37.0 8.4 47.8