Skip to main content
. 2023 Jan 25;20(1):016028. doi: 10.1088/1741-2552/acae0d

Table 3.

Static inductance and relative permeability as function of coil current. M3 Silicon steel (material #2) was modeled for the 20+20+6 experimental rat coil.

Coil current, A 100 1000 3000
Modeled inductance, µH 27.9 10.3 9.0
Average core µ r 99.5 7.6 2.9