Skip to main content
. 2023 Sep 7;21:189. doi: 10.1186/s12915-023-01686-z

Table 5.

Performance of deduplication tools in the Diabetes dataset

TP TN FN FP Sensitivity (SE) Specificity (SE) Precision F1 Time
Human 893 581 368 3 0.708 (0.013) 0.995 (0.003) 0.997 0.828 Unknown
EndNote 1218 584 43 0 0.966 (0.005) 1 (0) 1.0 0.983  < 5 min
SRA-DM 1147 514 114 70 0.91 (0.008) 0.88 (0.013) 0.942 0.926  < 5 min
ASySD 1259 584 2 0 0.998 (0.001) 1 (0) 1.0 0.999  < 5 min

TP True positives, TN True negatives, FN False negatives, FP False positives, SE Standard error