Table. 2.
The photovoltaic parameters of the OLPC with PB2:GS-ISO BHJ under different light sources
| Light source | I0 (mW cm−2) | Voc (V) | Jsc (mA cm−2) | FF (%) | PCE (%) | EQE (%)a |
|---|---|---|---|---|---|---|
| AM 1.5 G | 100.0 | 1.230 | 12.9 | 68.2 | 10.9 | – |
| λ660 | 1.9 | 1.120 | 0.7 | 79.8 | 32.6 | 68.9 |
| 3.0 | 1.140 | 1.2 | 80.4 | 34.9 | 71.4 | |
| 9.5 | 1.170 | 3.6 | 81.3 | 36.2 | 71.4 | |
| 24.9 | 1.190 | 9.7 | 74.8 | 34.7 | 73.2 | |
| 39.1 | 1.210 | 14.6 | 72.2 | 32.5 | 70.0 | |
| 84.7 | 1.230 | 30.8 | 69.8 | 31.3 | 68.4 | |
| 134.8 | 1.250 | 49.3 | 66.9 | 30.6 | 68.7 | |
| 211.2 | 1.260 | 75.3 | 64.6 | 29.0 | 67.0 |
aEQE calculated by Jsc.