4. Overview of included studies (PICO) ‐ Cardiovascular (vascular).
Study details | Population (surgery type) | CS detail | Intervention detail | Control detail | Outcomes reported (time point) |
Clagett 1999 RCT Registration: N/A Country: USA N = 100 | Vascular (aortic surgery: abdominal aortic aneurysm, aortofemoral bypass) | Timing of collection: intraoperative Washing: washed Transfusion threshold: Hb < 10 g/dL intraoperative; Hb < 8 g/dL postoperative; Hb < 10 g/dL cardiac System: Haemonetics Cell Saver (Haemonetics Corp, Braintree, Mass), or Cell Saver 3 Plus device or Cell Saver 5 device | Intraoperative autotransfusion (IAT) N = 50 | Control N = 50 |
|
Davies 1987 RCT Registration: N/A Country: Australia N = 50 | Vascular (abdominal aortic aneurysm or aortofemoral graft) | Timing of collection: intraoperative Washing: unwashed Transfusion threshold: Hct < 30% System: Sorenson system (Sorensen Research Co, Salt Lake City, Utah, USA) | Group A: autotransfusion (intra‐ and postoperative cell salvage) N = 25 | Group H: homologous transfusion without intraoperative salvage N = 25 |
|
Kelley‐Patteson 1993 RCT Registration: N/A Country: USA N = 36 | Vascular (aorto‐bifemoral bypass) | Timing of collection: intraoperative Washing: washed Transfusion threshold: Hb < 8 g/dL System: Cell Saver Autotransfusion Device (Haemonetics Corp., Braintree, Mass.) | AFB/CS N = 18 | AFB/no CS N = 18 |
|
Mercer 2004 RCT Registration: N/A Country: UK N = 81 | Vascular (abdominal aortic aneurysm) | Timing of collection: intraoperative Washing: washed Transfusion threshold: Hb < 8 g/dL System: Haemonetics Cell‐saver autologous blood recovery system (Haemonetics UK, Leeds, UK). | Intraoperative autotransfusion (IAT) N = 40 | Homologous blood transfusion (HBT) N = 41 |
|
Spark 1997 RCT Registration: N/A Country: UK N = 50 | Vascular ‐ Abdominal Aortic Aneurysm | Timing of collection: intraoperative Washing: washed Transfusion threshold: Hct < 25% System: COBE Baylor rapid autologous transfusion system (COBE laboratories Inc. Lakewood, Colorado, USA) | Autologous blood N = 23 | Homologous blood N = 27 |
|
Thompson 1990 RCT Registration: N/A Country: UK N = 67 | Vascular ‐ Abdominal Aortic Aneurysm | Timing of collection: intraoperative Washing: washed Transfusion threshold: Hb < 10 g/dL + Hct < 30% System: Haemolite® device (Haemonetics, Leeds, UK) | Cell Saver N = 33 | Controls N = 34 |
|
ANH: acute normovolemic haemodilution; AT: autotransfusion; CABG: cardiopulmonary bypass graft; CS: cell salvage; CVA: cerebrovascular accident; DVT: deep vein thrombosis; Hb: haemoglobin; Hct: haematocrit; LOS: hospital length of stay; MACE: major adverse cardiovascular events; MI: myocardial infarction; N: planned recruitment (as reported by the study); NA: not analysable; NR: not reported; PE: pulmonary embolism; PJI: prosthetic joint infection; RAP: retrograde autologous prime; RCT: randomised controlled trial; VTE: venous thromboembolism
"Registration: N/A" means 'not applicable' as the study was published before 2010 "Volume" refers to mean transfusion volume "Transfusions" refers to number of people receiving an allogeneic transfusion