Skip to main content
. 2023 Aug 31;13(17):2827. doi: 10.3390/diagnostics13172827

Table 6.

Performance comparison.

Method Accuracy Sensitivity Specificity AUC
PDF, PCA, SVM [45] 73.1 67.5 78.7 -
Complex network, SVM [17] 88 85 88 -
CNN(AlexNet), Transfer learning [22] 88.9 89.3 88.4 -
SVM [46] 92.3 90 94 97
GA-ELM [47] 89.22 92.35 92.35 -
SVM [44] 86.67 - - -
ResNet50 82 83.5 85 85.4
Proposed CNN Model 96 96.8 95.8 95