Skip to main content
. 2023 Aug 24;12(17):5498. doi: 10.3390/jcm12175498

Table 3.

Inter-rater reliability of the two experts and the algorithmic system. The following measured parameters were compared: mechanical axis deviation (MAD), mechanical lateral proximal femoral angle (mLPFA), anatomical mechanical angle (AMA), mechanical lateral distal femoral angle (mLDFA), joint-line convergence angle (JLCA), mechanical medial proximal tibia angle (mMPTA), mechanical lateral distal tibia angle (mLDTA), hip-knee-ankle angle (HKA), mechanical axis length (Mikulicz line) and leg axis (varus, valgus).

Inter-Rater Reliability-Rater 1 vs. Rater 2 vs. Software
Total Pre-Operative Post-Operative
n ICC 95% CI n ICC 95% CI n ICC 95% CI
MAD 150 1 0.99 1 70 1 1 1 80 0.99 0.99 1
mLPFA 155 0.93 0.91 0.95 75 0.93 0.89 0.95 80 0.94 0.91 0.96
AMA 155 0.81 0.75 0.86 75 0.89 0.83 0.92 80 0.73 0.61 0.82
mLDFA 155 0.87 0.85 0.91 75 0.83 0.75 0.89 80 0.98 0.96 0.98
JLCA 150 0.79 0.72 0.84 74 0.49 0.25 0.66 76 0.47 0.23 0.65
mMPTA 155 0.86 0.82 0.89 75 0.82 0.73 0.88 80 0.93 0.88 0.96
mLDTA 155 0.95 0.92 0.96 75 0.95 0.92 0.97 80 0.94 0.91 0.97
HKA 155 0.99 0.99 0.99 75 0.99 0.99 0.99 80 1 0.99 1
Mikulicz line 142 0.78 0.32 0.9 69 0.95 0.83 0.98 73 0.69 0.03 0.89
n Kappa 95% CI n Kappa 95% CI n Kappa 95% CI
Leg Axis 153 0.92 0.83 1.01 75 0.93 0.8 1.06 78 0.9 0.77 1.02

ICC: Intraclass Correlation Coefficient, CI: Confidence Interval.