Table 5.
T (°C) | t1/2 (h) | A1 | A2 | A3 | k1 | k2 | k3 | R2 | |
---|---|---|---|---|---|---|---|---|---|
CRL | 25 | 192 | −1.11 × 103 | 8.76 × 101 | 1.13 × 103 | 1.33 × 10−2 | 1.21 × 10−2 | 1.19 × 10−2 | 0.9836 |
40 | 35 | 1.05 × 102 | --- | --- | 2.29 × 10−2 | --- | --- | 0.981 | |
50 | 0.67 | 9.56 × 101 | --- | --- | 1.06 | --- | --- | 0.9891 | |
60 | 0.5 | 1.01 × 102 | --- | --- | 4.01 | 0.9977 | |||
70 a | --- | --- | --- | --- | --- | --- | --- | --- | |
CLEA-LC | 25 b | --- | --- | --- | --- | --- | --- | --- | --- |
40 | 312 | −1.66 × 101 | −1.23 × 101 | 1.29 × 102 | 2.51 × 10−2 | 2.51 × 10−3 | 2.51 × 10−3 | 0.9976 | |
50 | 96 | −3.12 × 102 | 1.39 × 101 | 3.97 × 102 | 2.86 × 10−2 | 1.98 × 10−2 | 1.99 × 10−2 | 0.9961 | |
60 | 2 | 4.65 × 101 | 5.15 × 101 | --- | 5.30 × 10−2 | 1.02 | --- | 0.9986 | |
70 | <0.5 | 2.80 × 101 | 7.20 × 101 | --- | 1.33 | 1.52 × 101 | 0.9984 |
a Deactivation too fast to be measured. b Deactivation not observed during the experiment.