Skip to main content
. 2023 Sep 4;24(17):13664. doi: 10.3390/ijms241713664

Table 5.

Deactivation parameters calculated from plots in Figure 9, according to a sum of exponential functions (Y = An·(exp(−kn)·X).

T (°C) t1/2 (h) A1 A2 A3 k1 k2 k3 R2
CRL 25 192 −1.11 × 103 8.76 × 101 1.13 × 103 1.33 × 10−2 1.21 × 10−2 1.19 × 10−2 0.9836
40 35 1.05 × 102 --- --- 2.29 × 10−2 --- --- 0.981
50 0.67 9.56 × 101 --- --- 1.06 --- --- 0.9891
60 0.5 1.01 × 102 --- --- 4.01 0.9977
70 a --- --- --- --- --- --- --- ---
CLEA-LC 25 b --- --- --- --- --- --- --- ---
40 312 −1.66 × 101 −1.23 × 101 1.29 × 102 2.51 × 10−2 2.51 × 10−3 2.51 × 10−3 0.9976
50 96 −3.12 × 102 1.39 × 101 3.97 × 102 2.86 × 10−2 1.98 × 10−2 1.99 × 10−2 0.9961
60 2 4.65 × 101 5.15 × 101 --- 5.30 × 10−2 1.02 --- 0.9986
70 <0.5 2.80 × 101 7.20 × 101 --- 1.33 1.52 × 101 0.9984

a Deactivation too fast to be measured. b Deactivation not observed during the experiment.