Table 5.
Flat-faced specimen transient tests mass loss and recession.
| Specimen | Test Condition * | Mass Loss (g) | Recession (mm) |
|---|---|---|---|
| Flat-20-2 | 6.259.4 MW/m2, 106.12 s | 12.35 | 6.73 |
| Flat-15-2 | 6.259.4 MW/m2, 108.8 s | 12.32 | 7.66 |
| Flat-10-2 | 6.259.4 MW/m2, 107.8 s | 11.57 | 7.55 |
Mass loss = specimen before test mass − specimen after test mass. Recession = specimen before test length − specimen after test length. * Actual test duration was confirmed using test video files.