Skip to main content
. 2023 Aug 24;21:4277–4287. doi: 10.1016/j.csbj.2023.08.020

Table 1.

Acquisition parameters of dynamic multiphase T1-weighted sequence.

Field Strength 1.5 T 3 T
Type of Acquisition 3D 3D
TR/TE (ms) 5.9/2.1 6.6/2.9
FOV (mm2) 256 × 256 256 × 256
Acquisition matrix 320 × 224 320 × 256
Reconstruction matrix 512 × 512 512 × 512
Pixel size (mm2) 0.8 × 1.1 0.8 × 1.0
Slice thickness (mm) 2 2
Slice spacing (mm) 1 1
Flip angle (°) 12 12
Number of phases 5 5
Temporal Resolution (s) 31 32
Acquisition time (min) 2 min 32 s 2 min 40 s