User variability across ROI selection methods for in vivo and ex vivo iron quantification. Reported average difference in mean (μg), SEM and CoV (%).
| ROI method | In vivo | Ex vivo (liver) | |||
|---|---|---|---|---|---|
| 1 (K = 5) | 2 (Liver) | 3 | 1 (K = 5) | 3 | |
| Avg. diff. mean (μg) | 68.62 | 102.46 | 475.73 | 29.62 | 38.34 |
| SEM | 51.82 | 76.96 | 404.25 | 16.76 | 25.48 |
| CoV (%) | 9.16 | 19.10 | 28.48 | 13.02 | 15.21 |