Skip to main content
. 2022;11(4):306–319. doi: 10.22088/IJMCM.BUMS.11.4.306

Table 3.

ROC analysis results for 14

Symbol AUC Std. Error 95% CI P value Sensiti
vity
95% CI Specifi
city
95% CI Optimal
Criterion
hsa-miR-221-3p 0.95 0.04 0.86 - 1.00 0.00 0.91 0.64-0.99 0.91 0.64-0.99 >8.82
hsa-miR-365a-3p 0.92 0.07 0.77 - 1.00 0.00 0.91 0.64- 0.99 0.91 0.64- 0.99 >8.72
hsa-miR-93-5p 0.88 0.07 0.73 - 1.00 0.00 1.00 0.75-1.00 0.83 0.55- 0.97 >8.64
hsa-miR-17-5p 0.87 0.08 0.71 -1.00 0.00 0.91 0.64-0.99 0.83 0.55- 0.97 >8.84
hsa-miR-424-5p 0.81 0.09 0.63 -1.00 0.00 0.66 0.39-0.86 1.00 0.75- 1.00 >9.47
hsa-miR-146b-5p 1.00 0.00 1.00 -1.00 0.00 1.00 0.75-0.86 0.91 0.64- 0.99 < 6.73
hsa-miR-497-5p 0.95 0.04 0.85 - 1.00 0.00 1.00 0.75-1.00 0.91 0.64-0.99 <7.71
hsa-miR-195-5p 0.97 0.03 0.91 -1.00 0.00 1.00 0.75-1.00 0.91 0.64- 0.99 <8.66
hsa-miR-181a-5p 1.00 0.00 1.00 -1.00 0.00 1.00 0.75-1.00 0.91 0.64- 0.99 <9.60
hsa-miR-135a-5p 1.00 0.00 1.00 -1.00 0.00 1.00 0.75-1.00 0.91 0.64- 0.99 <6.38
hsa-miR-125b-5p 0.85 0.08 0.69 - 1.00 0.00 0.75 0.46- 0.91 0.91 0.64-0.99 <12.22
hsa-miR-204-5p 0.90 0.07 0.75 - 1.00 0.00 0.91 0.64-0.99 0.91 0.64-0.99 <6.59
hsa-miR-340-5p 0.87 0.07 0.72 - 1.00 0.00 0.75 0.46-0.91 1.00 0.75-1.00 <6.53
hsa-miR-21-5p 0.79 0.09 0.59 -0.98 0.01 1.00 0.75- 1.00 0.66 0.39- 0.86 <15.02

AUC: Area under the ROC Curve; CI: Confidence Interval