Skip to main content
. 2023 Feb 14;37(14):2847–2854. doi: 10.1038/s41433-023-02438-7

Table 2.

OCTA machine and parameters of included studiesa.

Author, Country, Year OCTA machine OCTA parameters assessed within macula Macular scan diameter (mm)
Kwapong et al., China, 2018 Optovue Vessel density (%) of SVP, DVP and whole retinal capillary plexus (Ø 0.6–2.5 mm) and FAZ (mm2) 2.5
Berkowitz et al., USA, 2020 Optovue FAZ (mm2) 6
Rascunà et al., Italy, 2020 Optovue Vessel density (%) of SVP, DVP, outer retinal layer (whole [3 mm diameter circle], fovea [1 mm diameter circle] and parafovea [Ø 1-3 mm]) 3 and 4.5
Shi et al., China, 2020 Optovue Vessel density (%) and skeleton density (%) of SVP and DVP (Ø 0.6–2.5 mm) 2.5
Zou et al., China, 2020 Zeiss Perfusion density (%) and vessel length density (mm) of SVP (1 mm, 3 mm and 6 mm diameter circles, Ø 1-3 mm and Ø 3-6 mm) and FAZ (mm2) 6
Robbins et al., USA, 2020 Zeiss Perfusion density (%) and vessel density (/mm) of SVP (whole [6 mm diameter circle], parafovea [Ø 1-3 mm] and perifovea [Ø 3-6 mm]) and FAZ (mm2) 6
Zhang et al., China, 2021 SVision Flow density (mm2) and flow ratio (%) of SVP and DVP (whole [3 mm and 6 mm diameter circles] and fovea [1 mm diameter circle]) 6
Murueta-Goyena et al., Spain, 2021 Heidelberg Engineering Perfusion density (%), skeleton density (1/mm) and fractal dimension (Dbox) of SVP and DVP (whole [2.5 mm diameter circle], fovea [1 mm circle diameter] and parafovea [Ø 1-2.5 mm]) and FAZ (mm2) 2.5
Zhou et al., China, 2021 Zeiss Vessel density (/mm) of SVP (whole [6 mm diameter circle], fovea [1 mm circle diameter], parafovea [Ø 1-3 mm] and perifovea [Ø 3-6 mm]) and FAZ (mm2) 6 and 3

Meta-analyzed metrics of each study appear in bold.

aDVP deep vascular plexus, FAZ Foveal Avascular Zone (mm2), SVP superficial vascular plexus, Ø ring around fovea.