Skip to main content
. 2023 Aug 15;7(9):2300100. doi: 10.1002/gch2.202300100

Figure 5.

Figure 5

Number of touches to glove failure versus applied force ± standard error for Hevea latex, synthetic nitrile latex with colloidal oatmeal, and guayule latex. Each value is the mean of 3 gloves + standard error. Note: some error bars are smaller than the symbol height.