Skip to main content
. 2023 Aug 21;38:98–108. doi: 10.1016/j.jpra.2023.08.004

Figure 5.

Figure 5:

The final intraoperative measurement was performed after flap inset to assess the patency of the pedicle. In this case, DIEP flap was used for delayed breast reconstruction after a previous mastectomy. Note the good flap perfusion assessed by thermography and clinically.