Comparison of effective radiation dose on dual source computed tomography coronary angiography platforms in patients with Kawasaki disease

Ref.
Country
Number of cases
Platform
ECG triggering
Age
Radiation dose
Remarks
Duan et al[27], 2012 China 19 DSCT Prospective Range: 3 mo-5 yr ED (mean ± SD): 0.36 ± 0.06 mSv
Kim and Goo[28], 2013 Korea 51 DSCT: (1) 64-Slice: n = 49; and (2) 128-Slice: n = 2 Retrospective in most of the patients Mean (range): 13.2 (1-24) yr ED (mean ± SD): (1) 64-Slice: 2.6 ± 2.7 mSv; and (2) 128-Slice: 2.1 ± 0.6 mSv ED was only 0.6 ± 0.5 mSV in 5 children < 2 yr of age, who underwent prospective ECG-triggering
Ghoshhajra et al[29], 2014 United States 52 DSCT: (1) 64-Slice: n = 16; and (2) 128-Slice: n = 36 Prospective Range: 0-18 yr Median (IQR) ED: (1) 64-Slice: 2.9 (0.9-4.1) mSV; and (2) 128-Slice: 1.0 (0.6-2.0) mSV ED significantly reduced compared to 16 and 64-Slice Scanner platforms
Kantarcı et al[30], 2019 Turkey 17 128-Slice DSCT Details NA Mean (range): 3 yr (2 mo-11.3 yr) ED range: 1.2-4.3 mGy depending on the patient’s body weight
van Stijn et al[26], 2020 Netherlands 70 DSCT: (1) 2 × 192-Slice: n = 56; and (2) Other CT scanners (64/128/320-Slice): n = 14 Prospective Median (range): 15.1 (0.5-59.5) yr Median (range) ED: (1) 2 × 192-Slice: 1.5 (0.3-9.4) mSv; and (2) Other CT scanner: 3.8 (1.7-20.0) mSv This is the only study on 3rd generation DSCT platform
Borhanuddin et al[31], 2022 Malaysia 52 64-slice DSCT Retrospective Median (range): 5 (1-18) yr Median (range) ED: 0.81 (0.4-5.8)
Present study, Chandigarh India 85 128-Slice DSCT Prospective Median (range): 5 yr (2 mo-11 yr) Median (IQR) ED: 0.83 (0.68-1.01) Largest study on 128-Slice platform which provides data that CTCA can be performed in sub-millisievert doses