Effective computed tomography radiation exposure according to age in adaptive prospective electrocardiography-triggered sequence computed tomography coronary angiography on 128-dual source computed tomography platform

S.No.
Age group
Mean DLP (mGy.cm)
Mean effective radiation dose (mSv)
1 0-1 yr (n = 10) 9.19 ± 2.21 0.63 ± 0.16
2 1-5 yr (n = 29) 18.82 ± 8.48 0.85 ± 0.41
3 5-10 yr (n = 38) 31.79 ± 14.14 1.04 ± 0.37
4 > 10 yr (n = 8) 55.67 ± 19.39 1.38 ± 0.48

DLP: Dose length product; mSV: Millisievert.