TABLE 1.

Comparison of results of rapid immunochromatographic assay with those of capture ELISA for IgM and IgG antibodiesa

Rapid immuno- chromatographic test result No. of samples tested/no. (%) positive
IgM ELISA IgG ELISA
Reactive 5/6 (83)b 8/8 (100)
Weakly reactive 7/10 (70)c 9/19 (46)
Negative 0/27 (0) 0/16 (0)
 Total 12d 17e
a

n = 43. 

b

One sample which was negative on ELISA for IgM was positive for IgG by both tests. 

c

In these seven cases, secondary dengue was reported (positive for IgG by both tests; for IgM, the result was positive by ELISA and weakly reactive by the rapid assay). 

d

Of 12 IgM capture ELISA-positive patients, 4 had primary dengue infection. 

e

Of 17 patients, 7 had confirmed secondary dengue (IgM+, IgG+) and 10 were suspected of having secondary dengue (IgG+, IgM−).