Table 2.

Within-subject coefficient of variance (CoV) of the estimated semisolid MTC parameters, free bulk water T1 relaxation time, MTC at ±3.5 ppm, APT#, and rNOE# signal intensities obtained from Bloch fitting, BS/Recon-FCNN, BS/Recon-RNN and deepBS/Recon-RNN methods.

Coefficient of Variance
kmw F T2m T1w B1 = 1 μT B1 = 1.5 μT
MTC APT# rNOE# MTC APT# rNOE#
Bloch Fitting WM 4.3% 3.2% 0.7% 3.2% 0.5% 2.9% 2.4% 0.3% 4.9% 4.2%
GM 5.8% 2.7% 1.2% 2.0% 1.0% 4.1% 2.9% 0.8% 5.8% 6.9%
BS/Recon-FCNN WM 2.1% 1.1% 1.0% 2.1% 0.8% 1.8% 1.7% 0.7% 2.9% 2.8%
GM 5.3% 3.4% 1.3% 3.0% 1.2% 2.7% 2.4% 1.3% 3.0% 3.7%
BS/Recon-RNN WM 2.5% 1.4% 0.8% 2.1% 0.7% 3.0% 2.5% 0.6% 4.8% 4.2%
GM 4.8% 3.7% 1.6% 3.1% 1.2% 4.3% 3.3% 1.1% 5.9% 6.9%
deepBS/Recon-RNN WM 4.2% 1.4% 1.1% 1.6% 0.5% 2.7% 2.1% 0.5% 4.1% 3.0%
GM 6.3% 3.5% 1.8% 3.8% 1.3% 5.0% 4.2% 1.4% 8.4% 9.1%