Skip to main content
. Author manuscript; available in PMC: 2024 Oct 1.
Published in final edited form as: Magn Reson Med. 2023 May 29;90(4):1555–1568. doi: 10.1002/mrm.29712

Table 1.

Parameters used in the MOXE model, as determined from current literature for healthy populations.

Variable Description Literature value
SA/Vg (cm-1)  Alveolar surface area to volume ratio20 250
 d (μm) Total septum thickness28 12
δ (μm) Air-blood membrane thickness29 2.22
tX (s) Capillary transit time20 1.6
 D (cm2/s) Diffusion coefficient of dissolved xenon59 3.3×10−6
λ Ostwald solubility of xenon in lung parenchyma22 0.2
λRBC Ostwald solubility of xenon in RBCs60 0.19
λP Ostwald solubility of xenon in plasma60 0.091
Hb0 (g/dL)  Healthy reference value for volume of venous hemoglobin19 14
hr Ratio of regional pulmonary Hct to venous Hct25 0.9
a (dL/g) hr (Hct to Hb conversion factor61) (0.9) ⋅ (2.953×10−2)