Skip to main content
. 2021 Jul 1;2(1):511–522. doi: 10.5194/mr-2-511-2021

Table 1.

Experimental parameters used.

    Dimension of acquired data
Spectral width (ppm)
NS a d1 (s) b
    t1 t2 t3 F1 F2 F3    
Experiments with α -synuclein
1H detected
1H-15N HSQC
800 ( 15N )
2048 ( 1H )
 
28.1
15.0
 
2
1.0
13C detected CON 512 ( 15N ) 1024 ( 13C )   32.0 31.0   2 1.6
  CON Pro 128 ( 15N ) 1024 ( 13C )   5.0 31.0   2 1.6
  (H)CBCACONPro 128 ( 13C ) 32 ( 15N ) 1024 ( 13C ) 60.0 5.0 30.0 4 1.0
  (H)CCCONPro 128 ( 13C ) 32 ( 15N ) 1024 ( 13C ) 70.0 5.0 30.0 4 1.0
 
(H)CBCANCOPro
128 ( 13C )
16 ( 15N )
1024 ( 13C )
60.0
5.0
30.0
8
1.0
1H and 13C detected CON/HN 600 ( 15N ) 1024 ( 13C )   35.0 31.0   2 1.6
(using multiple receivers)
 
600 ( 15N )
2048 ( 1H )
 
35.0
15.0
 
4
 
Experiments with CBP-ID4
1H detected
1H-15N HSQC
800 ( 15N )
2048 ( 1H )
 
30.0
15.0
 
2
1.0
13C detected CON 1024 ( 15N ) 1024 ( 13C )   38.0 30.0   2 2.0
  CON Pro 170 ( 15N ) 1024 ( 13C )   6.5 30.0   2 2.0
  (H)CBCACONPro 128 ( 13C ) 64 ( 15N ) 1024 ( 13C ) 64.5 6.5 30.0 4 1.0
  (H)CCCONPro 128 ( 13C ) 64 ( 15N ) 1024 ( 13C ) 75.7 6.5 30.0 4 1.0
  (H)CBCANCOPro 128 ( 13C ) 22 ( 15N ) 1024 ( 13C ) 64.5 6.5 30.0 16 1.0
  (HCA)COCONPro 96 ( 13C ) 64 ( 15N ) 1024 ( 13C ) 10.8 6.5 30.0 8 1.5

a  Number of acquired scans. b  Inter-scan delay.