Skip to main content
. 2023 Aug 25;6(3):e1277. doi: 10.1002/jsp2.1277

TABLE 2.

Alignment measurements for spinal parameters measured preoperatively, 3‐month postoperatively, and 1‐year postoperatively reported as mean (SD). Statistical comparisons were performed between each time point within each measurement category. Significant p‐values (p < 0.05).

Preoperative 3‐months postoperative 1‐year postoperative
PJA (degrees°) 8.4 (7.8) 14.6 (11.0) 13.7 (10.3)
SVA (mm) 58.7 (56.3) 19.7 (32.6) a 9.7 (29.6) b
PT (degrees°) 24.9 (10.8) 21.9 (8.4) 20.5 (7.7)
PI (degrees°) 54.6 (14.9) 57.1 (13.8) 45.1 (41.2)
LL (degrees°) −30.2 (27.1) −47.4 (20.9) a −49.2 (15.3) b
PI‐LL mismatch (degrees°) 13.5 (34.9) 7.1 (10.6) −3.1 (38.8) b , c

Abbreviations: PI‐LL, pelvic incidence‐lumbar lordosis; PJA, proximal junctional angle; PT, pelvic tilt; SVA, sagittal vertical axis.

a

Adjusted p < 0.01 between preoperative and 3‐months postoperative.

b

Adjusted p < 0.01 between preoperative and 1‐year postoperative.

c

Adjusted p < 0.01 between 3‐months and 1‐year postoperative.