Table 4. Cutoff values, sensitivities, specificities and accuracy of RRI and serum creatinine in predicting the need for renal replacement therapy based on the ROC curve.
RRI: Renal resistive index
| Statistical parameter | RRI | Sr creatinine |
| Cutoff value | 0.73 | 2.33 mg/dl |
| Sensitivity | 35.1% | 86.0% |
| Specificity | 80.4% | 57.7% |
| Accuracy | 69.1% | 89.7% |