Table 1.
Overview of D-band technology platforms.
TECHNOLOGY* | Cost | Feature size | Tol. | SR | Scalability | MMIC int. | IL (dB/mm) |
---|---|---|---|---|---|---|---|
CNC12–15 | High | m | m | Medium | Low | Complex | 0.00715 |
DMLS / SLM18–22 | Medium | m | m | High | Low | Complex | 0.01918 |
SLA22, 23 | High | m | m | High | Low | Complex | 0.02522 |
Injection molding27, 28 | High | m | m | High | High | Complex | 0.04227 |
SU-813, 14, 31 | Medium | m | m | Low | Medium | Medium | 0.01131 |
SMW14, 33, 34 | Medium | m | m | Low | High | Medium | 0.0134 |
LTCC40, 41 | Low | m | m | Medium | High | Easy | 0.441 |
PCB (this work) | Low | m | m | Medium | High | Easy | 0.08 |
*The minimal feature size and tolerances (Tol.) are highly dependent on the chosen materials, the selected fabrication process and the surface finish.
SR is the surface roughness, SR can significantly be improved upon by employing (expensive) smoothing techniques, such as polishing.
IL is the lowest reported mean value of the insertion loss over the entire D-band, except for evaluated at 110 GHz.