Table 3.
Comparison of ORC results from the reference and the present study.
Parameter | Reference [44] | Present | Deviation (%) |
---|---|---|---|
WTUR (kW) | 114.07 | 113.3 | −0.68 |
WPU (kW) | 5.36 | 5.40 | 0.75 |
QEVAP (kW) | 1609.40 | 1630.92 | 1.34 |
QCOND (kW) | 1500.70 | 1522.99 | 1.49 |
mWF (kg/s) | 4.21 | 4.21 | |
mair (kg/s) | 26.86 | 26.86 | |
Wnet (kW) | 108.70 | 107.9 | −0.74 |
ηen,sys (%) | 6.75 | 6.62 | −1.93 |