Skip to main content
. 2023 Sep 5;9(9):e19829. doi: 10.1016/j.heliyon.2023.e19829

Table 4.

Summary of the CO2 removal efficiency and absorption flux of the pristine PP and FS-coated PP membranes.

Membrane Gas flow rate (mL/min) CO2 removal efficiency (%) CO2 absorption flux × 103 (mol/m2·s)
Pristine PP
50 100 2.55
100 100 5.11
200 100 10.22
400 89.6 18.32
800
51.4
21.01
FS-coated PP 50 100 2.55
100 100 5.11
200 99.4 10.17
400 70.2 14.35
800 43.3 17.70