Skip to main content
. 2023 Sep 7;9(9):e19959. doi: 10.1016/j.heliyon.2023.e19959

Table 3.

Fit of clasps at reference points (clasp tip, clasp arm, and occlusal rest) for each tooth position before and after cyclic testing.

Group Before circulation (μm)
After circulation (μm)
Clasp tip Clasp arm Occlusal rest Clasp tip Clasp arm Occlusal rest
PEEK 46 (n = 10) 66.25 ± 29.43 41.70 ± 32.41 110.54 ± 75.38 64.05 ± 29.50 64.47 ± 23.74 109.49 ± 50.03
Co–Cr 46 (n = 10) 70.63 ± 22.37 54.23 ± 28.51 170.29 ± 83.03 104.51 ± 47.91 80.71 ± 46.55 182.59 ± 97.89
PEEK 44 (n = 10) 70.84 ± 29.40 43.24 ± 32.50 79.93 ± 38.87 79.07 ± 25.79 66.28 ± 21.86 110.52 ± 43.44
Co–Cr 44 (n = 10) 71.82 ± 35.34 65.92 ± 75.43 99.28 ± 43.82 100.28 ± 41.98 84.61 ± 37.35 147.62 ± 113.94