Table 2.
Electrochemical parameters.
| Solution | Vitamin E concentration (mg/ml) | Ecorr (mV vs. SCE) | Icorr (μA/cm2) | Rp (ohms cm2) | Cf (μF/cm2) | Implant corrosion protection (%) |
|---|---|---|---|---|---|---|
|
| ||||||
| Saline | 0 | 0.04 | 1.12 | 3.90 | 1.29 | NA |
| ± | × | × 106 | × | |||
| 0.067 | 10“ 7 | ± | 10− 5 | |||
| ± | 5.21 | ± | ||||
| 3.84 | × 105 | 5.40 | ||||
| × | × | |||||
| 10− 8 | 10− 6 | |||||
| 1 | − 0.13 | 6.02 | 5.23 | 1.73 | NS | |
| ± | × | × 106 | × | |||
| 0.046 | 10− 8 | ± | 10− 5 | |||
| ± | 1.65 | ± | ||||
| 7.33 | × 106 | 1.93 | ||||
| × | × | |||||
| 10− 9 | 10− 6 | |||||
| 2 | − 0.07 | 7.62 | 4.38 | 1.90 | NS | |
| ± | × | × 106 | × | |||
| 0.134 | 10− 8 | ± | 10− 5 | |||
| ± | 3.99 | ± | ||||
| 3.99 | × 106 | 6.17 | ||||
| × | × | |||||
| 10− 8 | 10− 6 | |||||
| 3 | − 0.06 | 6.17 | 3.09 | 1.79 | 45 ± 0.9 | |
| ± | × | × 107 | × | |||
| 0.004 | 10− 8 | ± | 10− 5 | |||
| ± | 2.55 | ± | ||||
| 4.19 | × 106 | 4.10 | ||||
| × | × | |||||
| 10− 8 | 10− 6 | |||||
| BCS | 0 | − 0.74 | 1.58 | 4.18 | 2.99 | NA |
| ± | × | × 105 | × | |||
| 0.003 | 10− 6 | ± | 10− 5 | |||
| ± | 4.71 | ± | ||||
| 4.95 | × 105 | 7.20 | ||||
| × | × | |||||
| 10− 7 | 10− 6 | |||||
| 1 | − 0.74 | 1.63 | 3.64 | 3.21 | NS | |
| ± | × | × 105 | × | |||
| 0.002 | 10− 6 | ± | 10− 5 | |||
| ± | 4.06 | ± | ||||
| 3.13 | × 105 | 7.58 | ||||
| × | × | |||||
| 10− 7 | 10− 6 | |||||
| 2 | − 0.73 | *7.95 | *1.25 | 2.23 | 50 ± 3 | |
| ± | × | × 106 | × | |||
| 0.014 | 10− 7 | ± | 10− 5 | |||
| ± | 4.13 | ± | ||||
| 3.39 | × 105 | 4.09 | ||||
| × | × | |||||
| 10− 7 | 10− 6 | |||||
| 3 | − 0.37 | *1.22 | *2.64 | 1.88 | 91 ± 3 | |
| ± | × | × 106 | × | |||
| 0.288 | 10− 7 | ± | 10− 5 | |||
| ± | 3.88 | ± | ||||
| 4.74 | × 105 | 1.38 | ||||
| × | × | |||||
| 10− 8 | 10− 6 | |||||
Ecorr - corrosion potential; Icorr - corrosion current; Rp - polarization resistance; Cf - capacitance;