Correlation analysis for PM levels inside and outside subway stations.

Station PM Equations R Revised R2 Sig.
Closed system PM2.5 Y = 0.622X+91.093 0.880 0.742 0.020
PM10 Y = 0.641X+123.335 0.992 0.981 0.000
Screen door system PM2.5 Y = 0.602X+41.534 0.940 0.866 0.000
PM10 Y = 0.708X+46.103 0.991 0.980 0.000
Open system PM2.5 Y = 0.895X+0.522 0.857 0.697 0.003
PM10 Y = 0.902X-7.000 0.963 0.916 0.000