Skip to main content
. 2023 Aug;85(3):569–578. doi: 10.18999/nagjms.85.3.569

Table 1.

Patient demographics, LFCN-to-implant distance, LFCN position for end of rod, postoperative symptoms of LFCN disorder, and timing of device removal

Case Age (yrs) Sex Height (cm) Weight (kg) BMI AO/OTA classification Young-Burgess classification Time to surgery (days) Concomitant injuries LFCN-to-implant distance and LFCN position from the end of the rod Symptom of LFCN disorder Removal of device (months)
Right Left Right Left
1 28 M 169 62 21.7 61B2.2(c) LC-3 11 Right olecranon fracture Orbital blowout fracture 5 mm lateral 0 mm lateral + → – + → – 6
2 66 M 158 67 26.8 61B3.3(d) APC-3 17 No nerve below 50 mm No nerve below 50 mm + → + + → + 12
3 43 M 167 75 26.9 61B2.1(b) 62C3(f) LC-3 11 Pneumothorax, Left wrist fracture 10 mm lateral 10 mm medial + → – + → – 6
4 20 M 174 69 22.8 61B2.1(b) LC-1 7 Urethral injury No nerve below 50 mm No nerve below 50 mm + → – 6
5 70 F 151 50 21.9 61B2.1(a) LC-1 6 Right proximal humerus fracture 12 mm lateral 0 mm lateral + → + + → + 7
6 46 M 171 77 26.3 61B2.1(b) LC-3 7 0 mm lateral 0 mm lateral 5
7 55 M 156 57 23.4 61B2.1(b) LC-3 12 20 mm lateral 8 mm medial 4
8 71 F 146 49 23.0 61B3.3(b) APC-1 9 Left scapula fracture No nerve below 50 mm 10 mm medial
9 17 M 180 107 33.0 61B2.3(b) APC-2 8 Lumbar fracture Kidney injury 15 mm lateral 15 mm lateral 8
10 49 M 169 64 22.4 61B2.1(a) LC-1 12 Left wrist fracture No nerve below 50 mm No nerve below 50 mm 8
11 66 F 152 44 19.0 61C1.2(b,j) VS 11 Right femoral trochanteric fracture 10 mm lateral 0 mm lateral + → + 10
12 75 M 159 53 21.0 61B2.1(a) LC-1 11 Liver injury Pneumothorax 20 mm lateral 17 mm lateral 8
13 79 F 152 50 21.6 61B3.2(b) LC-3 17 Right clavicle fracture 20 mm lateral 25 mm lateral

BMI: body mass index

AO/OTA: AO Foundation/Orthopaedic Trauma Association

LFCN: lateral femoral cutaneous nerve

In cases where the LFCN was medial to the screw, the medial edge of the screw head was used to measure the LFCN-to-implant distance. In cases where the LFCN position was lateral to the screw, the end of the rod was used.

Symptom of LFCN disorder: (postoperative symptom) → (symptom after implant removal). +: symptom, –: no symptom